24.2- OPERATING OF THE "PO" (PRESENT ORDER) IN T70/1 and T70/2 PROPORTIONAL TRANSMITERS
Maintenance / Service
In the mechanisms block where the PO signals are generated as an OR function –using several diodes- with all
the digital input signals coming from the pushbuttons and the auxiliary inputs.
This PO signa lis used for the Present Order Circuitry" for secure and axternal auxiliary functions from the
microprocessor.
If it is required to remove the PO signals associated to digital maneuvers of the pushbuttons (M1, M3, M5, M7,
Dor the M23-M26 maneuvers the D3 diode must be removed from the PCB and for the M27-M30 maneuvers
the D6 diode must also be removed from the PCB
TM70Bi V4.1 (03/12)
1121174.pdf
IKUSI reserves the right to modify this information without prior notification.
M9, M11)
e.g. changing
pushbuttons to
selectors- the
corresponding
bridges
must
be
cut.
The
same
criteria
is used for the
auxiliary
maneuvers
M21 and M22.