b
Booster
C
Step-by-step modulation
C
Minimum rpm CH
c.
Minimum capacity modulating CH pump
D
Minimum rpm hot water
E
Min. leaving water temperature at OT
(OpenTherm) or RF thermostat
E .
Reaction OT and RF room thermostat
F
Start rpm CH
F .
Minimum start rpm hot water
h
Max. rpm fan
L
Legionella protection
N
Regulated temperature during boiler
operation (Ta)
n.
Hot water temperature at Comfort/Eco
O.
Wait time CH request response
O
Waiting time CH operation after hot water
operation
o.
Number of eco days
P
Anti-recycling time during CH operation
P.
Reference value hot water
q
Summer mode
r
Heating curve coefficient
0
0
0
Not applicable
1
1
1
0= step-by-step modulation off during CH operation
1= step-by-step modulation on during CH operation
2= Power control by Open Therm room thermostat
enabled
30
30
30
Setting reach 20 to 50%
40
40
40
Setting reach 15 to set value par. 3.
25
25
25
Setting reach 20 to 50%
40
40
40
Setting reach 10°C to 60°C
1
1
1
0= do not respond to hot water request if requested
temperature is lower than the set value par. E
1= respond to hot water request with minimum leaving
water temperature limited to set value par. E
2= respond to hot water request with maximum leaving
water temperature (on/off function)
70
60
50
Settings reach 40 to 99% of the set maximum rpm
70
60
50
Settings reach 40 to 99% of the set maximum rpm
50
50
50
Setting reach 40 to 50 (40=4000 rpm, 50=5000 rpm).
Please note: Factory setting, rpm may deviate
0
0
0
Not applicable (only for boilers with external DHW tank)
80
80
80
Setting reach 60°C to 90°C
0
0
0
Setting reach 0 or 40°C to 60°C
0 = reheating temperature is equal to hot water
temperature
0
0
0
Settings reach 0 – 15 minutes
0
0
0
Settings reach 0 to 15 minutes
3
3
3
Setting reach 0,1 to 10
0 = Comfort function controllable by Open Therm room
thermostat
1 – 10 number of eco days
5
5
5
Minimum switch off time on boiler water temperature
Can be set to 0 to 15 minutes
24
30
36
24 = RKOMBG22AAV1
30 = RKOMBG28AAV1
36 = RKOMBG33AAV1
0
0
0
0 = Summer mode deactivated
1 = Summer mode to be activated by
(code in display : Su)
2 = Summer mode to be activated by
(code in display : So)
3 = Summer mode to be activated by
(code in display : Et)
0
0
0
Not active
button
button
button
41