Shut-down/dismantling
8.2.2
Portable wet well installation
8.2.3

Clean and disinfect

▶ Pump has been cleaned. Pack and store the pump.
Installation and operating instructions Wilo-Rexa MINI3
1. Disconnect the pump from the mains.
DANGER! Have electrical work carried out by a qualified electrician!
2. Disconnect the connection cable from the pressure pipe.
3. Release the pump and discharge pipe from the pressure pipe.
4. Lift the pump from the operating space. CAUTION! Never pull the product by
the connection cable! Always carry the product by the handle.
5. Unscrew the discharge pipe from the pressure port.
6. Coil up the connection cable and store it with the pump.
7. Thoroughly clean the pump and discharge pipe (see "Cleaning and disinfecting"
chapter).
Pump has been taken out of service.
1. Disconnect the pump from the mains.
2. Lift the pump from the operating space. CAUTION! Never pull the product by
the connection cable! Always carry the product by the handle.
3. Undo the hose clip and remove the pressure hose from the pressure port.
4. Coil up the connection cable and store it with the pump.
5. Thoroughly clean the pump (see "Cleaning and disinfecting" chapter).
Pump is removed.
Drain the water used for cleaning into the sewage system.
Disinfectant is available.
1. Ensure that the plug or bare cable end is packed and stored in a watertight man-
ner!
2. Rinse the pump and cable with clean, running water.
NOTICE! When using disinfectants, strictly observe the manufacturer's spe-
cifications and instructions for use!
3. To clean the impeller and the pump interior, guide the water jet inside through
the pressure port.
4. Rinse attachments such as the discharge pipe and pressure hose with clean, run-
ning water.
5. Flush any dirt residue on the floor into the sewage drain.
6. Allow the pump to dry out.
7. Only clean the plug or bare cable end with a damp cloth!