spills from the tank surface and
its immediate surroundings. Re-
maining fuel can enter into a dan-
gerous reaction and cause a fire.
► CONNECTING THE TANK TO THE
BURNER (fig. 17)
The tank is fitted with two connector pipes
G1/4" to attach fuel lines as shown on the
illustration. Connector pipe A should be
connected to the line included in the fuel
filter kit, from the filter inlet side. Connector
pipe B should be connected to the burner
return line. Burner feed C should be con-
nected to the filter outlet C.
►►6. MAINTENANCE
The fuel inlet is basket type with filter which
stops impurities when the tank is filled up.
This filter requires additional cleaning.
Unless there are problems with filling up
the tank, the filter should be cleaned once
every 3 months.
Check the tank condition during use, see
if there are any fuel leaks. If the tank was
damaged, return it to the technical service
for repair.
It is possible for water to condense in the
tank. To prevent it from having an adverse
effect on device operation or tank durabili-
ty, it is recommended to drain the tank pe-
riodically, depending on the circumstances
or once in every 3 months. Use the outlet
plug (10) to empty the fuel tank.
WARNING!!! When cleaning the
filter, do not disassemble the inlet
as it may damage the insulation at
the connection point.