1.4.4 Technical Data AKD-xzzz07
Electrical data
Rated supply voltage
(L1/L2/L3)
Rated supply input fre-
quency
Rated input power for S1
operation @ 480V
Rated input current
at 3x240 V
at 3x400 V
at 3x480 V
Permitted switch on/off fre-
quency, mains
Max. inrush current
Rated DC bus link voltage
(Bus Turn on Delay 3ph 1s)
Regen circuit
max. continuous power
external regen resistor
Continuous output current ( ± 3%)
at 240 V
at 400 V
at 480 V
Peak output current (for 5s,
± 3%)
Continuous output power @ rated input current
at 3x240 V
at 3x400 V
at 3x480 V
Peak output power (for 1 s)
at 3x240 V
at 3x400 V
at 3x480 V
Noise emission (low
speed/high speed fan)
Mechanical data
Weight (standard width)
Weight (extended width*)
Dimensions
*= extended width: AKD drives with integrated IC, MC or M1 option card.
More technical data see Installation Manual.
Units
AKD-
AKD-
x00307
x00607
V
3 x 240 V to 480 V ±10%
Hz
AC with 50 Hz to 400 Hz ±5% or DC
kVA
2.24
4.49
A
2.7
5.4
A
2.7
5.4
A
2.7
5.4
1/h
A
10
10
V=
kW
1.5
3
Ohm
33
33
Arms
3
6
Arms
3
6
Arms
3
6
Arms
9
18
kVA
0.6
1.25
kVA
1
2
kVA
1.2
2.5
kVA
1.8
3.75
kVA
3
6.75
kVA
3.6
7.5
dB
34/43
34/43
(A)
kg
2.7
2.7
kg
2.9
2.9
mm
Kollmorgen | kdn.kollmorgen.com | December 2015
AKD Safety Guide | 1 English
AKD-
AKD-
x01207
x02407
7.65
15.2
9.2
18.3
9.2
18.3
9.2
18.3
30
10
20
340 to 680
6
12
33
23
12
24
12
24
12
24
30
48
2.5
5
4.2
8.3
5
10
6.25
10
10.4
16.7
12.5
20
44/52
48/58
2.7
5.3
2.9
5.5
see (➜ # 175)
AKD-
x04807
40.9
49.3
49.3
49.3
4
12
10
48
48
48
96
10
16.6
20
20
33
40
48/72
11.7
11.9
15