5 DESCRIPTION AND OPERATION OF THE CONTROLLER

Standby status-press "SET" button to enter operation parameter setting interface.
Press "SET" again to start setting (parameter from 00 to 09. See Operation Parameter's Table).
Under parameter setting, press
second to set data for parameter from 02-09.
No press in 5s, the LCD will display water-in/water-out temperatura (under running) or ambient temperature (unit stop).
Whilst running, you can press "SET" to check current parameter, but data can't be changed.
© ASTRALPOOL 2018. ALL RIGHTS RESERVED. CONFIDENTIAL AND PROPRIETARY DOCUMENT.
▲ ▲ ▲ ▲
"
"
"
"
or
to set data for parameter from 00-01, but must press
Parameter 00 to set the entering water temperature under cooling mode (8-28ºC).
Default setting = 27ºC
Parameter 01 to set the entering water temperature under heating mode (15-40ºC).
Default setting = 27ºC
ENGLISH
▲ ▲ ▲ ▲
"
"
"
"
and
for 3