NOTICE
Material and property damage due to missing
parts in the appliance.
Check the packaging for loose parts.
Do not dispose of loose parts; clarify their use with the
maintenance service (see → Maintenance services).
Start up the appliance
1. Connect the mains plug on the connecting cable
(see → Electrical connection).
2.
appears on the display, press
least 3 s (see → page 11, chapter 5).
After start-up, it may take up to 3 to 4 hours until the
desired temperature is reached.

10 Operation

Only trained operating personnel may operate the ap-
pliance.
WARNING
Damage to the electrical system and/or
the refrigerant circuit.
Contact with live parts may result in electric
shock. Flammable refrigerant can escape and
cause an explosive gas/air mixture. Fire haz-
ard due to sparking or overload.
Do not allow external forces to act
on the appliance, e.g. careless han-
dling with a lift truck or floor clean-
ing machine.
Avoid transmitting pulsations and vi-
brations to the appliance.
Observe safety notices and warnings
for appliances with flammable refrig-
erants (see → Flammable refriger-
ants).
If the appliance is damaged or the
fuse is tripped:
1. Disconnect the appliance.
2. Secure the appliance against reconnec-
tion.
3. Contact the maintenance service (see →
Maintenance services).
CAUTION
Glass / material breakage.
Body cuts. Impact injuries.
Do not apply any load to the lid.
Do not climb onto or into the appli-
ance.
Check glass elements and plastic
frames for damage, e.g. cracks,
breaks. In the event of damage,
promptly contact the maintenance
service (see → Maintenance ser-
vices).
405859_1_0819
Broken glass.
Hand and body cuts.
Leakage of condensation water.
Slipping hazard.
for at
Material damage due to misuse.
Operate the appliance in a stable operating
position (horizontal alignment).
Check that the appliance is in good, proper
condition. Any damage must be repaired im-
mediately.
Only operate the appliance with the sliding
feet mounted.
Property damage due to misuse.
Do not operate the appliance above the cli-
mate class stated on the rating plate (see →
Rating plate and serial number).
The ambient temperature must not fall below
16°C (60.8°F).
Observe the prescribed storage temperature
of the stored products.
Check the interior temperature (see → Tem-
perature display).
In the event of a power failure, stored goods
must be checked by the operating company
(temperature check).
Check the area in which goods are placed for
foreign objects. Remove goods stored incor-
rectly immediately.
Remove food residues, spilled liquids, and
packaging residues (see → Basic cleaning).
Only operate the appliance with its lids.
No objects may be stuck in-between the lid
and cover frame.
Check if the lid is closed.
For special climatic conditions with high humidity, con-
densation (condensation water) may form inside the
appliance or occur on the air outlets at the top. This
condensation must be removed for hygienic reasons.
Use protective gloves to remove split
glass parts and goods that may have
been damaged as a result.
Carefully and completely remove all
split glass parts and damaged goods.
Check for puddles in front of and un-
der the appliance.
Promptly remove leaking condensa-
tion water.
Contact the maintenance service
promptly (see → Maintenance ser-
vices).
NOTICE
Operation | 10
39 / 505

Hide quick links: