Electrical Connection - Hoshizaki KM-1301SAH-E Manual De Instalación

Productor de formas de hielo apilado
Ocultar thumbs Ver también para KM-1301SAH-E:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 18
Thermostat Extension
Bracket (stainless)
Thermostat Bulb
Attachment of
Thermostat
Lower Unit
Capillary Tubing
Fig. 5

6. Electrical Connection

Thermostat Bulb
Attachment
Removed from
Upper Unit
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the
national and local electrical code requirements.
To prevent possible severe electrical shock to
individuals or extensive damage to equipment,
install a proper earth wire to the icemaker. Turn
off the power supply before any maintenance,
Thermostat Bulb
repairs, or cleaning is undertaken.
• This icemaker must have a separate power supply
or receptacle of proper capacity. See the nameplate.
It is recommended that this icemaker be the only
electrical device on its power supply circuit.
• Stacked icemakers should each have a separate
receptacle, but they must all be connected in parallel
to the same single phase supply or circuit with
sufficient ampacity.
• The opening for the power supply connection is
22.2 mm diameter to fit a conduit.
• If a power cord is used to provide electricity to
the icemaker in place of the permanent (conduit)
connection, a gland should be installed at the
22.2 mm power supply connection. This gland should
be of the correct size for the power supply cord being
installed. The size of the conductors of this power
supply cord should be suitable for the electrical
consumption of this icemaker.
As the colours of the wires in the terminal box of this
appliance may not correspond with field supplied
wiring or with the markings identifying the terminals in
your power supply receptacle, proceed as follows:
The wire which is coloured Green-and-Yellow must
be connected to the terminal in the receptacle which
is marked with the letter E or by the symbol
coloured Green or Green-and-Yellow. The wire which
is coloured Blue must be connected to the terminal
which is marked with the letter "N" or coloured Black.
The wire which is coloured Brown must be connected
to the terminal which is marked with the letter L or
coloured Red.
• Usually an electrical permit and services of a licensed
electrician are required.
5