3. LOCATION
3. LOCATION
3. LOCATION
3. LOCATION
3. LOCATION
1. This icemaker is not intended for outdoor use.
Normal operating ambient temperature
should be within +7°C to +40°C. Normal
operating water temperature should be within
+7°C to +35°C. Operation of the icemaker,
for extended periods, outside of these nor-
mal temperature ranges may affect produc-
tion capacity.
2. The icemaker should not be located next to
ovens, grills or other high heat producing
equipment.
3. The location should provide a firm and level
foundation for the equipment.
4. Allow 15 cm. clearance at rear, sides and top
for proper air circulation and ease of
maintenance and/or service should they be
required.
5. This appliance is not suitable for installation
in an area where a water jet could be used
and where dripping is not allowed.
6. Do not place anything in front of the Louver.
7. This icemaker will not work at subfreezing
temperatures. To prevent damage to the
water supply line, drain the icemaker when
air temperature is below zero.
4. INSTALLATION
4. INSTALLATION
4. INSTALLATION
4. INSTALLATION
4. INSTALLATION
• The installation must be carried out by qualified per-
sonnel, in accordance with current regulations,
according to the manufacturer's instruction.
• Incorrect installation can cause harm to people, ani-
mals the icemaker, or the installation location, for
which the manufacturer cannot be held responsible.
1) Unpack the Storage Bin, and attach the four adjust-
able legs provided (bin accessory) to the bottom of
the Storage Bin.
2) Position the Storage Bin in the selected permanent
position.
3) Place the icemaker onto the top of the Storage Bin
taking care not to damage the bin top sealing gasket.
4) From the accessory pack, locate the two Universal
Braces and bolts to secure the icemaker to the Bin.
(See Fig. 2).
91A1NG11A0105
IMPORTANT
IMPORTANT
IMPORTANT
IMPORTANT
IMPORTANT
5) Level the icemaker/Storage Bin in both the left-to-
right and front-to-rear directions by turning the Bin
Leg Adjusters with a wrench.
6) Check that the Bin Control Bulb thumbscrews are
tight.
7) Replace the panels in their correct positions.

5. ELECTRICAL CONNECTION

5. ELECTRICAL CONNECTION
5. ELECTRICAL CONNECTION
5. ELECTRICAL CONNECTION
5. ELECTRICAL CONNECTION
THIS APPLIANCE MUST BE EARTHED
THIS APPLIANCE MUST BE EARTHED
THIS APPLIANCE MUST BE EARTHED
THIS APPLIANCE MUST BE EARTHED
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the
national and local electrical code requirements. To
prevent possible severe electrical shock to indi-
viduals or extensive damage to equipment, install a
proper earth wire to the icemaker. Turn off the
power supply before any maintenance, repairs or
cleaning is undertaken.
• This icemaker must have a separate power supply or
receptacle of proper capacity. See the Nameplate. It
is recommended that this icemaker be the only
electrical device on its power supply circuit.
• Usually an electrical permit and services of a licensed
electrician are required.
• Factory fitted power cords are coloured in accordance
with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
• Should the socket outlets in the installation site not be
suitable for the plug supplied with your product, the
plug must be removed (cut off if it is a moulded on
plug) and an appropriate plug fitted.
3
ENGLISH
Fig. 2
Fig. 2
Fig. 2
Fig. 2
Fig. 2
WARNING
WARNING
WARNING