Operating The Laser Receiver - Hilti PR 2-HS A12 Manual De Instrucciones

Ocultar thumbs Ver también para PR 2-HS A12:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 55
5.6 Checking the main and transverse horizontal axes
1. Set up the tripod approx. 20 m (66 ft) from a wall and adjust the tripod head horizontally with a spirit level.
2. Mount the tool on the tripod and use the visual sighting method (front and rear sights) to aim the tool at
the wall.
3. Fig. a: Use the receiver to catch the laser beam and mark a point (point 1) on the wall.
4. Pivot the tool clockwise through 90° about its own axis. In doing so, ensure that the height of the tool
does not change.
5. Fig. b: Use the laser receiver to catch the laser beam and mark a second point (point 2) on the wall.
6. Fig. c and d: Repeat the two previous steps twice and use the laser receiver to catch the beam and mark
points 3 and 4 on the wall.
Note
If the procedure has been carried out accurately, the vertical distance between the two marked
points 1 and 3 (main axis) or points 2 and 4 (transverse axis) should each be < 2 mm (at 20 m) (0.12" at
66 ft). If the deviation is greater than this, the tool should be returned to Hilti Service for calibration.

6 Operating the laser receiver

6.1 Inserting the batteries in the laser receiver
▶ Insert the batteries in the laser receiver.
Note
Use only batteries that have been manufactured in accordance with international standards.
6.2 Using the laser receiver to detect the laser beam
1. Press the
button on the laser receiver.
2. Hold the laser receiver with the receiving window directly in the plane of the laser beam.
3. Hold the laser receiver still while alignment is taking place and take care to ensure that the line of sight
between the laser receiver and the tool is not obstructed.
◁ Detection of the laser beam is indicated by visual and audible signals.
◁ The laser receiver indicates the distance to the laser beam.
6.3 Setting the units to be used
1. When switching the laser receiver on, press and hold the
◁ The menu is then shown in the display.
2. Use the
button to toggle between metric or imperial measuring units.
3. Switch the laser receiver off by pressing the
◁ The settings will be saved.
6.4 Changing the units used by the laser receiver
1. Switch the laser on. → page 19
2. Press the
button repeatedly.
◁ The desired accuracy (mm/cm/off) is shown alternately in the digital display.
6.5 Adjusting the volume level on the laser receiver
1. Switch the laser on. → page 19
2. Press the
button repeatedly.
◁ The desired volume level (low/normal/high/off) is shown alternately in the digital display.
Note
The laser receiver is set to "Normal" volume when switched on.
6.6 Adjusting the signal tone on the laser receiver
1. When switching the laser receiver on, press and hold the
◁ The menu is then shown in the display.
20
English
Printed: 01.09.2017 | Doc-Nr: PUB / 5260626 / 000 / 02
8
9
button for two seconds.
button.
button for two seconds.

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido