Volt-Ampere Curves; Remote 6 Receptacle Information (Stl And Sth Models Only) - Miller Maxstar 150 S Manual De Instrucciones

Ocultar thumbs Ver también para Maxstar 150 S:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3-5. Volt-Ampere Curves

115 VAC Input
100
80
60
40
TIG Min
20
Stick Min
0
0
50

3-6. Remote 6 Receptacle Information (STL And STH Models Only)

Volt-ampere curves show minimum and maximum voltage and amperage output capabilities
of welding power source. Curves of other settings fall between curves shown.
TIG/Stick Max
100
150
Amperes
15 VOLTS DC
OUTPUT
CONTACTOR
REMOTE
OUTPUT
CONTROL
CHASSIS
100
80
60
40
TIG Min
20
Stick Min
0
200
0
50
Socket
6
1
Contactor control +13.8 volts DC.
2
Contact closure to 1 completes contactor control
circuit and enables output when Lift-Arc TIG re-
mote is selected.
3
Output to remote control; +10 volts DC output to
remote control.
4
0 to +10 volts DC input command signal from
remote control.
5
Remote control circuit common.
6
Chassis common.
230 VAC Input
TIG/Stick Max
100
150
Amperes
208 604-B
Socket Information
OM-2242 Page 9
200

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Maxstar 150 stlMaxstar 150 sth

Tabla de contenido