8) What settings are required on the boiler display?
The desired water temperature; the boiler will then adjust the power accordingly to obtain or maintain this.
For small systems, a mode can be set that ignites and shuts down the boiler accordingly, as the water temperature is reached.
(contact DEALER for initial start up)
9) Can I burn other fuel apart from pellets?
NO. The boiler has been designed to burn wood pellets that are 6/8 mm in diameter. Any other material can damage it.
10) How long must the fume extractor fan operate during shut-off?
It is normal for the fume extractor fan to continue running for 15 minutes after the boiler shut-off command.
This method lowers the temperature of the boiler and the fume extraction channel.
11) When does the pump (circulator) start working?
It starts up immediately after boiler ignition, to keep the temperature of the water uniform, and it stops after the shut-off proce-
dure, when the water temperature has fallen below the SET value (factory setting: 40°C).
12) What operations can be carried out from the control panel, if I have installed the DOMOKLIMA GRAPHICA console?
You can set the ignition/shut-off timetable of the boiler (if the POWER MODULATION mode is enabled on the DOMOKLIMA
GRAPHICA console), set manual ignition/shut-off of the boiler if the system stops and reset the alarm.
13) Can I release the alarms from the DOMOKLIMA GRAPHICA console?
No, in the case of a stoppage, you can only take action from the control panel on board the boiler. This is for safety and to check
the state of the boiler before re-ignition.
To be integrated with a complete reading of the technical specifi cations
Positioning and installation
•
Start up by authorised technical assistance centre which has issued the guarantee
•
Room ventilation
•
Only theboiler outlet passes through the smoke channel/chimney fl ue
•
The smoke channel has: a maximum of 3 curves
•
The exhaust pipes are made of suitable material (recommended: stainless steel)
•
When using any fl ammable materials (e.g. wood), all precautions have been taken to prevent a fi re hazard
•
The heating capacity has been appropriately assessed considering radiator effi ciency:
how many kW have been estimated to be necessary???
•
The hydraulic system has been declared to be compliant with the Ministerial Decree 37 ex Law No. 46/90 by a qualifi ed
technician.
Use
•
Good quality, dry pellets are used
•
The chimney pot and ash compartment are clean and well positioned.
•
The door is closed properly
•
The combustion chamber is inserted properly into the relevant compartment
•
The exchanger tubes and internal parts of the hearth are clean.
•
The bleeding process has been applied to the hydraulic system.
•
Pressure (read on the pressure meter) is at least 1 bar.
REMEMBER TO VACUUM THE COMBUSTION CHAMBER BEFORE EACH IGNITION
Should ignition fail, DO NOT re-ignite until you have emptied the combustion chamber.
Ash vacuum cleaner without motor (code 275400)
Used for cleaning the hearth
FAQ
CHECK LIST
a maximum of 2 horizontal metres
CLEANING ACCESSORIES