BERING MUST NEVER BE MADE TO OPERATE WI-
THOUT WATER IN THE SYSTEM.
IT CAN BE DAMAGED IF IT IS IGNITED WITH NO WA-
TER IN THE SYSTEM.
MUST BE MADE WITH A PRESSURE OF ABOUT 1.5 BAR.
• BERING is designed to heat water by means of automatic
combustion of pellets in the hearth.
• The only risks that may derive from using the pertain to non-
compliance with the installation regulations, direct contact with
live electrical parts (internal), contact with the fi re or hot parts,
or foreign substances being put into the boiler.
• Should components fail, the boiler are equipped with safety
devices that guarantee automatic shutdown. These are activated
without any intervention required.
• In order to function correctly, the boiler must be installed in
accordance with the instructions given herein and the door
must not be opened during operation: combustion is fully
automatic and requires no intervention.
• Only use wood pellets
6/8 mm in diameter
• Under no circumstances should any foreign substances be put
into the hearth or the hopper.
• Do not use fl ammable products to clean the smoke channel
(the fl ue section connecting the boiler smoke outlet to the
chimney fl ue).
• Do not clean when hot.
• Hearth and hopper components must only be cleaned with a
vacuum cleaner.
• Make sure the boiler is installed and ignited the fi rst time
by Edilkamin-qualifi ed CAT personnel (technical assistan-
ce centre) in accordance with the instructions provided here
within; this is an essential requirement for the validation of the
guarantee.
IMPORTANT!!!
In the case of a fi re in the boiler, in the fl ue or in the chimney, proceed as follows:
- Disconnect the power supply
- Use a carbon dioxide (CO
- Call the fi re brigade
DO NOT ATTEMPT TO PUT THE FIRE OUT WITH WATER!
After the event, have the appliance checked by an authorised Service Centre and have an authorised technician check the
fl ue.
SAFETY INFORMATION
as fuel
) extinguisher
2
• When the boiler is in operation, the exhaust pipes and door
internal become very hot (do not touch without wearing the
thermal glove).
• Do not place anything, which is not heat resistant near the
boiler.
• NEVER use liquid fuel to ignite the boiler or rekindle the
embers.
• Do not obstruct the ventilation apertures in the room where
the boiler is installed, nor the air inlets of the boiler itself.
• Do not wet the boiler and do not go near electrical parts with
wet hands.
• Do not use reducers on the smoke exhaust pipes.
• The boiler must be installed in a room that is suitable for fi re
prevention and equipped with all that is required (power and
air supply and outlets) for the boiler to function correctly and
safely.
• The boiler must be kept in a room where the temperature is
above 0 °C.
• Use appropriate anti-freeze additives for the water of the
system.
• In the event that the water used for fi lling and toping up
has a hardness greater than 35° F, use a water softener. For
suggestions please refer to regulation UNI 8065-1989 (Water
Treatment In Heating Systems For Civil Use).
• Should ignition fail, DO NOT re-ignite until you have
emptied the combustion chamber.
ATTENTION:
THE PELLET EMPTIED FROM THE COMBUSTION
CHAMBER MUST NOT BE DEPOSITED INSIDE THE
HOPPER.
- 31
-