Installation Instruction - Stainless Steel Installation
STEP 3 INSTALL WATER LINE
WARNING
Connect to potable water supply
only. A cold water supply is required for automatic
icemaker operation. The water pressure must be
between 40 and 120 psi (275-827 kilopascals).
WARNING
ELECTRIC SHOCK HAZARD
Attach tubing clamp using existing hole only. DO NOT
drill into the refrigerator.
AVERTISSEMENT
Raccordez l'appareil à une
alimentation d'eau potable seulement. Une alimentation
d'eau froide est requise pour faire fonctionner
la machine à glaçons et le pichet à remplissage
automatique. La pression d'eau doit se situer entre 40
et 120 psi. (275 à 827 kPa).
AVERTISSEMENT
Fixez le collier de serrage dans le trou présent seulement.
NE PERCEZ PAS dans le réfrigérateur.
ADVERTENCIA
Realice la conexión a un
suministro de agua potable únicamente. Se requiere
un suministro de agua fría para el funcionamiento de la
máquina de hielos automática y de la jarra de llenado
automático. La presión del agua deberá estar entre 40
y 120 p.s.i. (275 – 827 kPa).
ADVERTENCIA
Adhiera la abrazadera de la tubería usando el agujero
existente únicamente. NO perfore el refrigerador.
• The tubing should be long enough to extend to the
front of the refrigerator. Allow enough tubing to
accommodate the bend leading into the water line
connection.
RISQUE DE DÉCHARGE
ÉLECTRIQUE
PELIGRO DE DESCARGA
ELÉCTRICA
Floor
Cold Water Line
NOTE: The only Monogram approved plastic tubing is
supplied in the SmartConnect
Do not use any other plastic water supply line because
the line is under pressure at all times. Other types of
plastic may crack or rupture with age and cause water
damage to your home.
SmartConnect
™
Refrigerator Tubing Kits are available in
the following lengths:
2' (.6 m)
WX08X10002
8' (2.4 m)
WX08X10006
15' (4.6 m) WX08X10015
25' (7.6 m) WX08X10025
Shut off the main water supply.
Turn on the nearest faucet long enough to clear the line
of water.
• Install a shut-off valve between the icemaker water
valve and cold water pipe in a basement or cabinet.
The shut-off valve should be located where it will be
easily accessible.
• Turn on the main water supply and flush debris. Run
about a quart of water through the tubing into a bucket.
Shut off the water supply at the shut-off valve.
NOTE: Saddle type shut-off valves are included in many
water supply kits. Before purchasing, make sure a saddle
type valve complies with your local plumbing codes.
NOTE: Commonwealth of Massachusetts Plumbing
Codes 248CMR shall be adhered to. Saddle valves
are illegal and use is not permitted in Massachusetts.
Consult with your licensed plumber.
36
Refrigerator Tubing kits.
™
31-1000450 Rev. 1