Beninca CP.BULL8 Manual De Instrucciones página 15

Ocultar thumbs Ver también para CP.BULL8:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
In the tables hereunder the single functions available in the control unit are shown.
mENU
Automatic closure time. It is activated only with "TCA"=ON logic.
TCA
At the end of the preset time, the control unit controls a closure opera-
tion.
Operating time. The operating time is adjusted during motor opening and
TM
closing phases.
The area covered by the gate during its partial opening movement (pe-
Tped
destrian) is adjusted.
The area covered by the gate during the braking phase is adjusted.
Tsm
0 = braking disabled
PMo
The torque applied to the motor in the opening phase is adjusted.*
PMC
The torque applied to the motor in the closing phase is adjusted *.
The torque applied to the motor during braking in the closing phase is
Pso
adjusted.*
The torque applied to the motor during braking in the opening phase is
Psc
adjusted *
The intervention threshold of the anti-crashing device (Encoder) during
SeaU
the phase at normal speed is adjusted.*
1:maximum sensitivity - 99: minimum sensitivity
The intervention threshold of the anti-crashing device (Encoder) during
SEAR
braking is adjusted *.
1:maximum sensitivity - 99: minimum sensitivity
Activated only with SERL:ON Logic. The activation time of the service light
TLS
is adjusted.
The force of the motor brake is adjusted.
Ibra
0: disabled braking - 1:minimum braking - 99: maximum braking
* WARNiNG: An incorrect setting of these parameters may cause danger.
mENU
The automatic closure is enabled or disabled
TCA
On: enabled automatic closure
Off: disabled automatic closure
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse
IbL
of the transmitter have no effect in the opening phase.
Off: disabled multi-flat function.
The rapid closure is enabled or disabled
On: rapid closure is enabled. When the gate is open or moving, the photocell
SCL
activation causes the automatic closure of the gate after 3 s. It is activated only
with TCA:ON
Off: rapid closure is disabled.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before
PRE
the starting of the motor.
Off: disabled forewarning flashing light.
During the TCA time, the blinker is enabled or disabled.
LTCA
On: Activated blinker.
Off: De-activated blinker.
PARAmETERs, LoGiCs ANd sPECiAL FUNCTioNs
FUNCTioN
Please comply with regulations in force!
FUNCTioN
mEmo
miN-mAX-(default)
1-240-(40s)
1-250-(90s)
20-250-(50 cm)
0-250-(0 cm)
1-99-(50%)
1-99-(50%)
1-99-(50%)
1-99-(50%)
0-99-(0%)
0-99-(0%)
1-240-(60s)
0-99-(50%)
mEmo
dEFAULT
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
15

Publicidad

Tabla de contenido
loading

Tabla de contenido