The control unit checks the correct operation of the safety devices. In the event of faults the following messages can be
displayed:
Error, stroke self-learning or remote control code memorisationi.
ERR
Error, PHOTOTEST PHOT O.
ERR1
Error, PHOTOTEST PHOT C.
ERR2
Error, Encoder.
ERR3
Let us suppose it is necessary to:
- set an automatic closing time (TCA) of 100s
- activate pre-blinking
Perform the operations described below step by step:
step
Press
display
1
2
3
4
5
6
7
8
9
10
11
12
13
If the product must be dismantled, it must be disposed according to regulations in force regarding the differentiated waste disposal and
the recycling of components (metals, plastics, electric cables, etc..). For this operation it is advisable to call your installer or a specialised
company.
18
EXAmPLE oF PRoGRAmmiNG
First menu
PAR
First function of the first menu
TCA
Value currently set for the function selected
040
Set the desired value with the <+> and <-> keys
100
The value is programmed
PRG
When programming has been made, the display goes to the function just set
TCA
Press <+> and <-> simultaneously to go to the higher menu
PAR
Second menu
Log
First function of the second menu
TCA
Press <-> several times to select PRE logic
Pre
Value currently set for the function selected
OFF
Set the desired value with the <+> and <-> keys
ON
The value is programmed
PRG
When programming has been made, the display goes to the function just set
Pre
Press <+> and <-> simultaneously to go to the higher menu and quit programming or
PAR
wait 30s.