Advanced Set-Up - Sime ECOMAXI 90 ErP Manual De Instalación, Uso Y Mantenimiento

Calentador de agua con bomba de calor
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation, use and maintenance manual
7.1.3.6
Setting the time brackets for switching
the appliance on and off
NOTE:
before
operation at pre-set times, set the current
day and time by following the procedure
in section 7.1.3.14.
To access the procedure:
Make sure that the keypad is not locked and
that there are no other advanced procedures
running;
Press and release the
on the display.
To set the first time bracket:
Press and release the
button within 15 seconds to select "HOn1" (first
ON time) and/or "HOf1" (first OFF time);
select"HOn2" and "HOF2" for the second
ON/OFF;
Press and release the
Press and release the
button within 15 seconds;
Press and release the
touch the display for 15 seconds;
To associate a time bracket with a day of the
week:
Following on from the previous point, press and
release the
button or the
within 15 seconds to select "Hd1" (ON time for
day 1/Monday) and/or "Hd2...7" (ON time for
days 2-7/Tuesday-Sunday);
Press and release the
Press and release the
button within 15 seconds to select "1" (first
ON/OFF time) or "2" (second ON/OFF time);
Press and release the
touch the display for 15 seconds;
To exit the procedure before completion:
Do not touch the display for 15 seconds (any
changes are saved) or press and release the
button.
Carefully consider any activation of the
automatic ON/OFF time settings so as to
avoid causing a disservice to the users.
7.1.3.7
Displaying the operating status
Make sure that the keypad is not locked
(section 7.1.3.3) and that there are no other
advanced procedures running;
Press and release the
corresponding to the current active operating
mode
is
displayed
(Auto/ECO/Obst/Anti).
activating
automatic
button: "SP1" shows
button or the
button;
button or the
button or do not
button
button;
button or the
button or do not
button: the code
for
3
seconds
7.1.3.8
Silencing the alarm
To silence the alarm, do as follows:
Ensure that there is no other advanced
procedure running;
Press any button once.

ADVANCED SET-UP

NOTE: the instructions below are for
specialist technical support personnel.
7.1.3.9
Conditions for starting the different
operating modes
Each operating mode must respect specific
conditions in order to be activated:
AUTOMATIC mode
The condition for starting up this function is as
follows: lower probe < SP2 – r0 (hysteresis);
ECO mode
The condition for starting up this function is as
follows: lower probe < SP1 – r0 (hysteresis);
OVERBOOST mode
The condition for starting up this function is as
follows: lower probe < SP3 and upper probe <
SP3. Once a temperature above SP3 has been
detected, Overboost mode stops and the
appliance returns to the operating mode
previously set.
7.1.3.10 Display
If the appliance is ON, during normal operation the
temperature detected via parameter P5 is shown
on the display:
If P5 = 0, the temperature of the upper part of
the boiler is displayed;
If P5 = 1, the active operating setpoint is
displayed;
If P5 = 2, the temperature of the lower part of
the boiler is displayed;
If P5 = 3, the evaporator temperature is
displayed;
If the appliance is in stand-by mode, the
display is off.