Setting The Day And Time - Sime ECOMAXI 90 ErP Manual De Instalación, Uso Y Mantenimiento

Calentador de agua con bomba de calor
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation, use and maintenance manual
7.1.3.11 Alarms
AL
Minimum temperature alarm
Solutions:
- Check the temperature associated with the
alarm;
- See parameters: A0, A1, A2 and A11.
Main consequences:
- The appliance continues to function normally
AH
Maximum temperature alarm
Solutions:
- Check the temperature associated with the
alarm;
- See parameters: A3, A4, A5 and A11.
Main consequences:
- The appliance continues to function normally.
When the cause of the alarm disappears, the
appliance resumes normal operation.
7.1.3.12 Errors
Pr1
Upper boiler probe error
Solutions:
- Check that the type of probe corresponds to
the setting under parameter P0;
- Check that the probe is integral;
- Check the connection between the appliance
and the probe;
- Check the temperature of the upper part of
the boiler.
Main consequences:
- The appliance stops working.
Pr2
Lower boiler probe error
Solutions:
- As above only in relation to the probe for the
lower part of the boiler.
Main consequences:
- The appliance stops working.
Pr3
Evaporator probe error
Solutions:
- As above only in relation to the evaporator
probe.
- The appliance stops working.
When the cause of the alarm disappears, the
appliance resumes normal operation.
7.1.3.13 Defrosting
Defrosting can be activated as follows:
Automatically,
when
temperature falls below the temperature set
under parameter d17 (only if P4 is not 0);
In any case, between one defrosting cycle and
the next, the compressor must have been on for at
the
evaporator
least 18 minutes. Otherwise, the defrosting request
is not accepted.
If P4 = 1, d2 is the evaporator temperature above
which defrosting stops. Vice versa, if P4 = 0 or P4 =
2, the parameter d2 is not considered.
If, when defrosting, the evaporator probe is above
the threshold set under parameter d2 and
parameter P4 = 1, the defrosting request is not
accepted.
Defrosting is made up of the following stages:
Defrosting phase: parameter d3 determines
the
maximum
duration
Output statuses:
Compressor
active
-
otherwise off;
Defrost relay active where d1 = 0.1,
-
otherwise off;
Fans on where d1 = 2, otherwise off.
-
Dripping phase: parameter d7 determines the
duration
of
Output statuses:
Compressor off;
-
Defrost relay active where d1 = 0.1,
-
otherwise off;
Fans off.
-
Drying phase: parameter d16 determines the
duration of this phase. Output statuses:
Compressor according to parameter d8;
-
Defrost relay active where d1 = 0.1,
-
otherwise off;
Fans on.
-
If
the
Anti-legionella
Overboost
function
defrosting is not activated.

7.1.3.14 Setting the day and time

Make sure that the keypad is not locked
(section 7.1.3.3) and that there are no other
advanced procedures running;
Press and release the
available code is shown on the display;
Press and release the
button until you see "rtc";
The day is shown in the format 1-7 (1 =
Monday, etc.).
To change the day of the week:
Press and release the
followed by two numbers indicating the day
are shown on the display;
Press and release the
button within 15 seconds.
To change the time (hours):
Press and release the
changing the day of the week: "hh" followed
by two number indicating the time are shown
on the display (24-hour clock);
MANUAL CODE: 6328406
of
this
phase.
where
d1
=
1,
this
phase.
function
or
the
is
in
operation,
button: the first
button or the
button: "dd"
button or the
button when
Page 49 / 124

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

8115800

Tabla de contenido