4.4

Adjusting the device

Pos : 71 /DinA4 - Anl eitungen Onli ne/Ueberschriften/3./Absc hlus s widerstand @ 19\mod_1321958079906_15.doc x @ 110083 @ 3 @ 1
Pos : 72 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Bedienung/Absc hl uss widerstand setzen 83220-AP- xxx @ 19\mod_1310723392369_15.doc x @ 107841 @ @ 1
4.4.1

Terminal resistor

Fig. 35: Terminal resistor
Pos : 74 /DinA4 - Anl eitungen Onli ne/Inhalt/KN X/D oor Entr y/Bedienung/Master/Sl ave Schalter s etz en 83220-AP- xxx @ 19\mod_1310723320966_15.doc x @ 107833 @ @
No.
Functions
1
Station
Select switch to set the address of default outdoor station.
2
X10 X1
Select switches to set the address (0-99) of the indoor station.
Setting hundreds ,see Chapter 4.2.12.15 "setup".
3
Master/slave function
Only one indoor station in each apartment should be set as "master"
(Switch should be set as "M/S on.") All additional indoor stations in the
same apartment must be set as "slave" (Switch should be set as "M/S
off.")
4
Terminal resistor
In video installations or mixed audio and video installations, the switch
should be set as "RC on" on the last device of the line.
|