Commissioning/start-up
Attention! Sensitive electrical components.
Possible consequence: The unit will be destroyed.
Protective measure: Do not connect the unit to a dimmable power supply.
OASE recommends the use of BioKick (OASE filter starter bacteria):
− For the initial start-up
− After manual cleaning of the foam filters
− After fitting new foam filters
− When recommissioning following a storage period/over-wintering
Prior to using filter starter bacteria ("Filter starter"), operate the unit for approx. 24 hours without switching on the UVC
unit. If you do not use filter starter bacteria, commissioning can start directly with the "Fitting connections" step.
How to proceed:
− Open the container ( Cleaning and maintenance\Opening the container).
− Fill the filter starter bacteria (adhere to the attendant instructions for use!).
− Close the container ( Cleaning and maintenance\Closing the container).
− Fit the connections (
− Check the firm seating of hoses, cover cap for soiled water drain, clamping ring with safety latch.
− Turn the function switch (J 5) to water filtering (40), if it is not already in this position.
− Switch on the pond pump.
− Only switch on the UVC unit when water is flowing through it. You may have to wait for 24 hours.
Connect power plug to the socket. The UVC unit switches on immediately, the blue LED (J 33) is lit.
Operation
The unit is no longer biologically active at water temperatures below 10 °C. Take the unit out of operation at water
temperatures below 8 °C or, at the latest, when freezing temperatures are to be expected.
Normal operating condition: The UVC unit is switched on. The UV-C lamp must be replaced after approx. 8000 opera-
ting hours.

Remedy of faults

Malfunction
No water flow through the return
socket.
UVC lamp display is not lit
Filtering performance not
satisfactory

Wear parts

The UVC lamp, the quartz glass and the foam filters are wear parts and are excluded from the warranty.
Assembly).
Cause
− Filter pump not switched on.
− Supply lines blocked.
− Function switch not turned to "Filter water"
− Connection defective or has not been made.
− Temperature monitor has switched off the UVC
lamp
− UVC lamp defective
− Quartz glass tube not fitted
− Function switch not turned to "Filter water"
− Unit has not been in operation long enough
− Water extremely soiled
− Excessive fish and animal population
− Foam filters clogged
− Quartz glass tube soiled
− UVC lamp is in operation for more than 8000 hours − Replace UVC lamp
Remedy
− Switch on the filter pump
− Check supply lines
− Turn function switch to „Filter water"
− Check connection (power plug, power fuse)
− Allow the UVC lamp to cool down
− Replace UVC lamp
− Fit quartz glass tube
− Turn function switch to „Filter water"
− Wait a few days/weeks
− Adhere to the reference value
− Clean foam filters
− Cleaning the quartz glass tube