System message
Functions that are still
available
E
r
3
3
E
r
3
3
20 cleaning cycles in
succession
60
Possible cause
Manual cleaning
Level detection device stuck or
Time-dependent cleaning
defective
Screen elements heavily soiled
Rinsing pump not operating
Rinsing nozzles clogged
Filter drum not rotating
Gravity fed systems only:
Water level is beneath the level
detection device
Level detection device set too high
Water level in the system too low:
Excessive flow quantity (pump
capacity too high)
Water supply too low
Water inlet blocked
Pump fed system only:
Level detection device set too low
Water level in the system too high:
Outlet pipes soiled
Outlet opening too small
Excessive flow quantity (pump
capacity too high)
Remedy
Clean the level detection device to ensure that the
mechanics operate freely, replace if necessary
Clean and decalcify screen elements (→ Replacing screen
element)
Clean the bottom of the container, clean the rinsing
pump(
Cleaning/disassembling the rinsing pump)
Check the pump connection
Clean the rinsing nozzles
Check the motor connection
Check the rotating movement of the filter drum. To do so,
check the markings (1 - 8) on the filter drum to detect a
rotating movement.
Increase the water level of the pond
Use the OASE ProfiClear Guard refill system
Adjust the level detection device (→ Adjusting the level
detection device)
Reduce flow quantity (adjust pump capacity)
Select a larger pipe diameter for the water supply if
necessary
Clean water inlet
Adjust the level detection device (→ Adjusting the level
detection device)
Clean outlet pipes
Enlarge outlet opening
Reduce flow quantity (adjust pump capacity)
Resetting the system
message