System message
Functions that are still
available
E
r
4
4
E
r
4
4
Motor blocked
None
(The control system
attempted to start up the
motor three times - 5 times
per attempt)
Possible cause
Remedy
Filter drum rotating sluggishly or
Clean edge of the drum/drum seal and grease edge of the
jammed
drum Only use original OASE grease (order number
27872).
Ensure that the rollers move smoothly
Remove larger particles (e.g. snails, stones) from the
sprocket
The lips of the drum seal were
Disassemble the drum and ensure that the drum seal is
squeezed when the drum was installed.
positioned correctly during re-assembly
The drum load is distributed unevenly
Align the container horizontally
Pump fed system only:
More than 15000 l/h of water flowing in
Limit the flow rate per inlet to 15000 l/h.
through one inlet have pushed the drum
Use an additional inlet to split the flow quantity.
aside.
Water level too low
Ensure that the water level in the drum filter is 230 ... 350
mm below the edge of the container.
Solo operation: Position the outlet higher.
Recommendation: Use a Oase outlet set. (→ Solo
operation, drum filter module)
Solo operation: Install a vent in the pipe lines of the outlet
to prevent negative pressure. (→ Solo operation, drum filter
module)
Gravity fed systems only:
Excessive difference in water level inlet
Determine the cause of the difference and eliminate it (e.g.
side/drum side
level detection device set too deep, screens clogged,
rinsing function inactive)
Switch off the pumps and wait until the water level is equal
on both sides. Subsequently, switch on the pumps again
and check the difference.
- GB -
Resetting the system
message
On|Off
Press key
for 5 sec
61