SELFLEARNING AND DEFAULT PARAMETERS
The control unit is pre-set with the default settings, to start the control unit with the
DEFAULT settings just keep pressed the UP and DOWN buttons at the same time power
supplying the control unit the display shows the message init.
The DEFAULT settings are shown in the Menues table.
WORKING TIMES SELF LEARNING
Note1: Put a jumper on SAFETY EDGE contact if not used.
Note2: It is not necessary to put a jumper on the limit switches, photocells and Stop if they
are not used.
1) Check the right operation of the accessories (photocells, buttons etc.).
If necessary set the leaf delay.
2) If necessary adjust the selflearning speed.
3) Switch off power supply (Fig. 1), release the motors (Fig. 2-3) and manually place the leaf on
the middle of the stroke (Fig. 4).
Restore the mechanical lock (Fig. 5-6)
4) Power the control unit (Fig.7)
5) Choose the desired motor type; use (default Flipper).
6) Select prog on the display, press OK and then UP and DOWN to start the programming.
Note3: If on single leaf mode set MONO on ON.
Note4: If one or both motors start in opening, switch off power and invert the motor(s) cable starting in opening.
Afterwards repeat the procedure starting from point 4, or activate IN. T.
7) Both leaves will start a CLOSE - OPEN - CLOSE cycle automatically (CLOSE M2 - CLOSE M1 - OPEN M1 -
OPEN M2 - CLOSE M2 - CLOSE M1).
End of selflearning.
BETA
Release
Fig. 2
BETA
Lock
Fig. 5
67410756
®
FLIPPER
Operator
M1
released
Fig. 3
Operator
locked
English
Fig. 4
FLIPPER
A
N
O
Fig. 6
Fig. 7
REV 04 - 03/2013
USER 2 - 24V DG
Fig. 8
M1
M2
Fig. 9
M1
Fig. 1
O
F
F
M2
M2
27