START (N.O.) The
START is connected between the clamps 2 and 3 of the CN 1 terminal.
An impulse given to this contact opens and closes the automation depending onthe selected logic it can be given by a key switch, a keypad,
etc. To connect the other devices refer to the related instructions leaflets. (ie. loop detectors and proximity switches).
Note1: In DEAD MAN logic it is necessary to keep pressed the Start for the opening of the automation.
Note2:
In 2 BUTTONS logic this button performs the opening.
Timer activation: it is possible to connect a timer on the start only in auto logic with time of pause different than DISB and with START IN
PAUSE function OFF.
Can be activated through on-board display or through the Jolly programmer. In both cases it's a N.O. contact which provoques the opening of the
TIMER
automation keeping it open until it is activated. When it's released, the gate attends the set pausing time and executes the reclosing. The TIMER
command can be activated on the inputs FOTO2, START PEDESTRIAN.
Note1: When activated on the pedestrian entry, the pedestrian will be disabled also on the radio transmitter.
Note2: In case of intervention of a security device during the timer (Stop, Ammeter, Edge), to restore the movement it will be necessary to give a
start impulse.
Note3: In case of no power supply with open gate and active Timer the control unit will restore its use, otherwise if during restore of the power
supply the TIMER is not activated it will be necessary to give a start impulse for the reclosing.
67410756
®
Photocell 1 and Photocell 2 Connections
+ = 24VL
Note1: For the autotest connect the TX to the 24VL clamp and activate the Autotest function.
Note2: The Ph. e will keep the photocells OFF while the gate is closed, thus saving energy.
Note3: On the Ph. T e menu you can also activate the self-test even on the single photocell.
2
1
The standard setting of the photocell 1 is FOTO CLOSE and the one of the photocell 2 is FOTO
OPEN.
The selftest can be applied also on single photocell.
OPTIONS ON FOTO1 and FOTO2 adjustable on on- board display or with JOLLY terminal.
FOTO CLOSE activation (
prevent the closing.
Activation repeat pause (rP. P A): If occupied, during pause it recharges the timer of pause. In
closing it reverses the movement.
FOTO OPEN activation (oPEn): If activated the photocell blocks the movement as long as it's
busy, when released the opening continues.
FOTO PARK activation (
1
2
3
Options 24AU
It is possible to chose when having tension on the 24AU output. The options are: always,
only during opening, only during cycle, only before opening or only during pause.
When using control units with batteries and / or solar panels, we recommend connecting
RX1
the accessories which are not used when operator stands still (e.g. photocells) to a
24VAux output, setting the option "Op. L". With this setting you can save energy by
lowering power consumption in stand-by, increasing the autonomy of the system.
CN2
5 6
5
6
5
6
English
COM = 0V
PH1 = Photocell contact 1
The photocell 2 can be set also as TIMER (see TIMER function).
Los
): if occupied, reverses the movement in closing, during pause it
Par
): in opening it is not active; in pause are activated it commands the
closing when released, otherwise it's not active; in closing it stops the movement as long
as it is busy, when released the closing continues.
FOTO STOP activation (STOP): When activated before the opening the photocell blocks
the automation as long as it is busy, during the opening it will be ignored. In closing the
intervention of the photocell causes the reopening.
Activation PHOTO CLOSE IMMEDIATELY: The photocell stops the gate as long as it is
occupied in both opening and closing, when released it gives a closing command
(Closing one second after release of the photocell ).
can be set with on-board Display or with Jolly device.
PEDESTRIAN START (N.O.) The pedestrian start can be connected
between the clamps 2 and 4 of the CN1 terminal .
This input allows a partial opening the opening space can be set through the
on-board display or through the JOLLY device.
Note1: The contact for partial opening is a N.O. Contact (Normally open).
Note2:In 2 BUTTONS logic it is necessary to keep pressed the Start Ped. to
re-close the automation.
Note3: In dead man logic this button executes the re-closing if you keep it
pressed.
Note4: When closed during pause, the gate will reclose only after this input
has been reopened.
TIMER activation: This input can be transformed into TIMER (See TIMER).
STOP (N.C.) The STOP is connected between the clamps 2 and 5 of the CN1
terminal .
The pressure on this button immediately stops the motor in any
condition/position. A start command is needed to re-start the movement.
After a stop the motor always re-starts in closing.