Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
PROGRAMMER JOLLY PARAMETERS ADJUSTMENT
Screen 9
Flash
Photo1
Photo2
8k2 edge
Screen 10
Timer
Pos. Recovery
24V aux
Start pause
Screen 11
Mot.inv.
Start
Rev. Mot.
P.Ped
Screen 12
Tl.op.1
Tl.cl.1
Tl.op.2
Tl.cl.2
Screen 13
Push ov.
Leaf Stroke
P.O.PR.
Lock
Screen 14
L.Timer
Screen 15
Event
40
67410756
®
[Normal/Control/always/beep]
[Close/Open/stop/park/close imm./rel.pause]
[Close./Open/stop/park/close imm./rel.pause]
[On-Off] (On ON it allows to connect a balaced edge with 8k2
resistance)
[OFF-Ped-Foto2] (Allows the timer activation on the Foto2 or
pedestrian input)
[0÷100]% (Percentage of position recovery)
[Cycle/in open /in clos./pause/ph.test/ph.T.ECO/always]
[ON/OFF] (On ON and if the autom. clos. is on ON a start will
cause the immediate closure of the gate)
[ON/OFF] (Allows to changes at the same time the limit switch
and the direction of motor rotation without disconnecting the cables)
[ON/OFF] (Equivalent to giving a test start)
[0÷100%] (Activates an inversion at the end of closing)
[start, Off, 0÷240 sec] (Differenciates the pedestrian pause from the
total one)
[0÷ 100%] (Tolerance between stop and obstacle)
[0÷ 100%] (Tolerance between stop and obstacle)
[0÷ 100%] (Tolerance between stop and obstacle)
[0÷ 100%] (Tolerance between stop and obstacle)
[Off,open., close.,Open.cl.] (Activates the motors at max. torque
at the end of closing or opening or in both cases)
[0÷3 sec] (Facilitates the electrolock release)
[0÷8 ore] (Activates the periodic Push Over with stoped motors)
[0 a 5s] (Activates the click of the lock from 0 to 5 seconds)
[Off-On] Allows to keep switched on or off the control light if a Timer
is active
Summarizes the last 10 events that occurred on the unit
English
REV 04 - 03/2013
USER 2 - 24V DG