Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
SAFETY GATE OR AMPEROMETRIC MANAGEMENT
AMPEROMETRIC DEVICE FOR ELECTROMECHANICAL OPERATORS
This control unit comes with an obstacle detection system working only on electromechanical operators allowing to
have the reversing on obstacles and the automatic detection of the stops.
The sensitivity is adjustable for single leaf and single opening and closing direction through the torque parameter.
SAFETY GATE
The Safety Gate is an ENCODER allowing the detection of the gate position
and its reversing in case of obstacles. To use the ENCODER it is necessary
to enable it inside the special ENC Menu. The sensitivity on the obstacle is
adjustable from 0 - 99%. The higher the percentage is the more it will be
difficult to detect the obstacle.
A T T E N T I O N : T h e f i r s t
operation after power failure, will
be executed with the set speed
to search the mechanical stops
limit.
ELECTRO- LOCK AND WARNING LAMP
CN2
1 2 3 4 5 6 7 8 9
5
TIMEABLE COURTESY
LIGHT OUTPUT
Max 500 mA
13
12
11
10
9
8
12
13
34
67410756
®
SAFETY GATE 1
9
7
8
ELECTRO- LOCK
CN1
7
6
5
4
3
2
WARNING LAMP
English
SAFETY GATE 2
Electro-lock exit
An electro-lock of 12V
possible to disactivate the electroc-lock if not used. This
operation allows to save energy of the control unit. The
release of the electro-lock can be timed' from 0 to 5 s.
Flashing Lamp 24VL
24VL
The warning lamp advises that the automatic gate is in
movement performing 1 flash /second in opening and 2
flashes / second in closing. Instead it remains turned on fix
during pause.
To connect it, connect the wires of the warning lamp as
shown in the figure.
flash 24V Led.
Pre-flashing form 0 to 5 seconds can be activated before
operator start or only before closing.
1
Furthermore from the flashing lamp it is possible to verify
some alarm signals. See alarms indications.
It is possible to set this exit with fixed flashing also when the
gate is not moving or it is possible to change this exit into
9
control lamp.
remain on the warning lamp as long as they are active.
11
SAFETY EDGE
It is possible to connect an active safety edge on the
terminal CN1. If this device is pressed it opens the contact
causing a partial inversion of the movement both in opening
and in closing. If not used bridge the contacts 9 and 11 of
CN1. Note: contact N.C.
REV 04 - 03/2013
USER 2 - 24V DG
1
+24V
1
1
15W max can be connected. It is
15W (Warning lamp ) /
4W Led
Note: It is recommended to use the
In such case all the indications of alarm
CN7
2
3
4
ENC1
ENC2 GND
2
3
4
3
4