SELECTION OF THE SETTINGS
The settings of the control unit are made through the UP, DOWN and OK buttons. The UP and DOWN buttons to scroll through
the MENUS and SUBMENUS. By pressing OK you enter from MENU into SUBMENU and confirm the choice.
Pressing the UP and DOWN buttons at the same time you access the SP MENU for special settings. Pressing the OK button for
5 seconds, you enter the TEST MENU, where you can check the operating status of all inputs.
DISPLAY INPUT STATUS
pedestrian
Start
Limit
Switch
MENU
opening
---
motor 1
----
Limit
----
Switch
closing
motor 1
Photocell 1
(To access the Menu for input TESTS keep pressed OK for about 5 seconds)
MENU
Description
strt
Start test
stop
Stop test
pedo
Pedestrian start test
edgE
Safety edge test
Pko. 1
Photocell 1 test
Pko. 2
Photocell 2 test
F o. i
M1 opening limit switch test
F
. 1
M1 closing limit switch test
F o. 2
M2 opening limit switch test
F
. 2
M2 closing limit switch test
0. 0
Batteries' voltage level
28
67410756
®
Start
Stop
SEA
SET
When the segment is
O N d u r i n g s e l f -
learning, the input
status is closed or
OFF.
Edge 1
Edge 2
Photocell 2
MENU FUNCTION board USER 2 24V DG INPUT TESTS
The contact must be a N.C. Contact. If activating the related command on the display
The contact must be a N.C. Contact. If activating the related command on the display
The contact must be a N.C. Contact. If activating the related command on the display
The contact must be a N.C. Contact. If activating the related command on the display
The contact must be a N.C. Contact. If activating the related command on the display
sure that the contact is a N.C. contact or that the related limit switch is not occupied.
The contact must be a N.C. Contact. If activating the related command on the display
sure that the contact is a N.C. contact or that the related limit switch is not occupied.
The contact must be a N.C. Contact. If activating the related command on the display
sure that the contact is a N.C. contact or that the related limit switch is not occupied.
The contact must be a N.C. Contact. If activating the related command on the display
sure that the contact is a N.C. contact or that the related limit switch is not occupied.
English
Limit Switch
opening motor 2
Limit Switch
closing motor 2
The contact must be a N.O. Contact . When activating the related command
on the display SET lights up, the input works.
If SET is always on, check the wirings.
SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
The contact must be a N.O. Contact . When activating the related command
on the display SET lights up, the input works.
If SET is always on, check the wirings.
SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
SET lights up, the input works.
If SET is always on, make sure that the contact is a N.C. Contact
SET lights up, the input works. If SET is always on, make
SET lights up, the input works. If SET is always on, make
SET lights up, the input works. If SET is always on, make
SET lights up, the input works. If SET is always on, make
Batteries charge level indicator
REV 04 - 03/2013
USER 2 - 24V DG
Initial system
u. 0 01
Software Version
Programming example
Sl d
UP
UP
ot
TRAI
OK
DOWN
UP
barr
Description
UP
OK
DOWN
OK
DOWN
OK
DOWN