SELECTION OF THE SETTINGS
PRESS AT THE SAME TIME FOR 5 SECONDS TO ENTER OR TO EXIT THE SPECIAL MENU
DOWN
UP
(To enter the Special Menu keep pressed UP and DOWN at the same time for 5 seconds.
To exit the Special Menu pressed END or keep pressed UP and DOWN at the same time for 5 seconds)
MENU SP
Description
Motor M1 speed
Sp. 1
Motor M2 speed
Sp. 2
Slowdown speed
Sl. d n
Learning speed
Sp. l r
tr. o p
Leaf delay setting in opening
tr. c l
Leaf delay setting in closing
. O p1
M1 opening torque
M1 closing torque
L1
M2 opening torque
. O p2
M2 closing torque
L2
PushOver
Pu Ou
R. s tr
Reversing Stroke
Sd. o 1
M1 opening slowdown
Sd. c 1
M1 closing slowdown
Sd. o 2
M2 opening slowdown
M2 closing slowdown
Sd. c 2
pr. b l.
Pre-flashing
Flashing lamp or Buzzer output
Lg. b u
Motors and limit-switch inversion
N. T
Encoder activation
Enc
Courtesy light
L. O
Pedestrian opening
Ped. o
30
67410756
®
SPECIAL MENU FUNCTIONS TABLE USER 2 24V DG
SET
30 100
30 100
30 100
D sb 6
D sb 20
0 100
0 100
0 100
0 100
Disb
Op. c l
O. o pe
O. c lo
D sb 3
D sb 50
D sb 50
D sb 50
D sb 50
D sb
1, 2 , 3
l. o n
alys
La p
spy
Beep
off
on
On Off
Y l
1, 2 , 3
20 100
English
Description
Motor M1 speed
Motor M2 speed
Learning speed
Setting from OFF to 6 seconds
From OFF to 20 seconds setting
Opening torque M1
and amperometric sensitivity
Note: By increasing the torque
the sensitivity decreases
Closing torque M1
and amperometric sensitivity
Note: By increasing the torque
the sensitivity decreases
Opening torque M2
and amperometric sensitivity
Note: By increasing the torque
the sensitivity decreases
Closing torque M2
and amperometric sensitivity
Note: By increasing the torque
the sensitivity decreases
OFF
Opening an closing
Opening only
Closing only
From OFF to 3 seconds
From OFF to 50% of the stroke
From OFF to 50% of the stroke
From OFF to 50% of the stroke
From OFF to 50% of the stroke
OFF
Adjustable from 1s to 5s
Only before closing
Flashing lamp always on
Classic flashing light
Control lamp
Buzzer
Synchronized right motor
Synchronized left motor
In On enables the Encoder reading
Only during cycle active.
Courtesy light setting from
1s to 4min.
Pedestrian opening space adjustment
REV 04 - 03/2013
USER 2 - 24V DG
Default
Set value
75
75
30
50
3
3
70
70
70
70
D sb
D sb
30
30
30
30
D sb
La p
off
Off
Y l
100