2.2
INSTALLATION
IT
ES
2.2. 1
CONFIGURATION OF THE BOILER FOR THE USE WITH PELLETS AND OPTIONAL KIT
PT
A) Remove the blind flange in cast iron and disassemble the grille, hinge and hake along with the setting screws.
GB
Fig. 13: Disassembly of blind flange
B) Assemble the five baffles supplied, pushing the first deflector against the rear head of the boiler and then the others.
Fig. 13.2: Assembly of baffle
C) Disassemble the boiler thermostatic valve, if present, and close the hole with the cap supplied. Disassemble also the boiler thermometer, if fit-
ted, and close the hole on the front piece with the plastic cap supplied.
Fig. 13.4: Assembly of cap
78
Fig. 13. 1 : Disassembly of grille
Fig. 13.3: Assembly of baffle
Fig. 13.5: Closing the front piece