The system pump
doesn't work
The burner get dirty
very quickly
Smokes loss
(pellet mode)
Pellet stops into the
flexible tube
Primari fan stop
The pellet descent
self-extinguishing
pipe has melted.
Check if the summer function is active.
Check the right plug-in.
The pump can be blocked, burned-off or air into the
system.
Enabling from ambient thermostat missing (or the
bridging on the plug - in case the termostat is not
available - is missing - in this case the pump led is
flashing).
Low quality pellet (too dusty pellet or excess of
bark and of mineral residuals, hampring the,
automatic removal during the cleaning).
Underpressure is not eneugh.
Pellet's diameter <> 6mm.
Check the right closing of the front doors and of
the top cover.
Check the burner's seal is well fastened to the door.
Check the right connection between boiler's
smokes outlet and the chimney.
Check the right position
Too much sawdust. Clean it.
Low quality pellet which tends to stick to the coilholder
slide thus hampering the descent.
Set boiler's temperature is reached (MAnt).
Boiler's OFF.
The fan is blocked or broken: contact the nearest
service center.
Door open (Por) (only on boiler's prepared
for this.
Action of the safety system (melting of the pipe)
to physically separate the pellet storing chamber
from the burner in case of back-fire.
Always replace the pipe with a self-extinguishing pipe to
avoid affecting the safety device described above.
Underpressure is not enought into the chimeny.
Low quality pellet obstructing the burner.