N) Push the feeder volute with the motor into its slot inside the pellet container (with a 200 -500 dm
IT
bucket is pointing upwards. Fix the volute onto the container using the screws that are already available on the container.
ES
PT
GB
Fig. 13.21: Insertion of the volute into the pellet container
O) Connect the 10 pole connector (JB) on the control panel to the burner, safety sensor and to the volute motor power plug.
Fig. 13.23: Assembly of connector JB
P) Assemble the burner motor verifying that it is correctly connected to the safety sensor.
Fig. 13.26: Assembly of burner cover
M) Connect the flexible self-extinguishing pipe with the straps to the burner and pellet feeding volute. Verify that the tube is fully stretched to pre-
vent it from blocking the pellets.
Fig. 13.28: Fixing the lower section of the flexible tube
82
Fig. 13.22: Volute fixing
Fig. 13.24: Connection of sensor
Fig. 13.27: Checking the sensor connection
Fig. 13.29: Fixing the upper section of the flexible tube