IT
The automatic pellets
charging doesen't work (2)
ES
PT
GB
Ignition doesen't take
place after the second
attempt
The boiler is
temporary blocked
In pellet mode
the boiler doesn't reach
the set temperature
and it does'nt keep 60°C
The main switch's
les is 'on' but the
elboard does'nt start.
The main switch
does't light on
90
Alt +
The pellet's safety sensor shut-off: remove the
tPEL
connector and make the manual rearmament (it
is released at 90°). Check the reason of temperature
resing is this position (cleaning, burner full of ash,
dirty smoke duct or chimney depression not correct).
Breakage of the safety sensor on the inlet of the
pellet chamber or electric contact of said sensor
interruptes along its line to the central unit.
The thermal disjunctor acts.
Press the reset button.
Alt +
Check the cleaning of the photocell on the burner
ACCF
on the burner.
Check the ignition coil is working.
Check the pellet's quantity loaded for the ignition.
Pellet must cover at least 50% of the diagonal grid on the
back of the burner's combustion chamber.
Check the primary fan working.
Check the cleaning of the burner's grid.
The thermal disjunctor acts.
Press the reset button.
Alt +
The electronic coil reed a temperature over
SIC
95°C. Check the working of the system pump (she
is forced in this moment). N.B. the alarm is
automatically reset when the boiler's
temperature decrease.
'Summer' function active and water temp. In the
boiler set over 80°C: decrease this set point.
The system water does 'nt circulate well.
Air into the system.
The size of the boiler is not correct for the system
to which it is connected, or the thermal flywheel
is too large. Close the system at the start to allow
for the thorough warming up of the accumulator.
Insufficient pellet capacity:
- Check the screw position and the capacity
- Pellet quality or sizing causing anomalies
in the capacity.
Mixing valve not present into the heating circuit
Electronic board's fuse burned-off:exange it
with a fuse of the same Ampere type delayed.
Check the 220V electricity feeding and the
connection of his plug.
Broken led.