• Locate a stud within the wall to attach the mounting bracket and
receptacle. For concrete or masonry walls, install appropriate
anchors.
• Verify that the stud or anchor and surrounding materials can
handle the 20+ lbs load of the VersiCharge.
• Verify local code with respect to installation height:
• Installation height is regulated by NEC®, however this can
vary based on local jurisdiction.
• NEC® 2011specifies:
• Receptacle should be
installed prior to mounting the
VersiCharge to the wall.
• Wire receptacle using
appropriate wire and a
standard NEMA 6 receptacle.
• Using 7/16 inch socket head
and drill, attach the Mounting
Bracket to the wall using the
two lag screws, using the
cutout to line up with the
receptacle (see photo).
© 2012 Siemens Industry, Inc.
• Indoor (NEC® Article 625.29B) = installation 18 - 48