POSSIBLE TROUBLESHOOTING

(intervenes if the ow sensor detects insuf cient combustion ).
Air ow may be insuf cient because the door is open, the door does not close properly (e.g. bad seal), there is an
air intake or smoke e traction problem, or the combustion chamber is clogged.
heck:
door closure;
combustion air intake duct (clean, paying attention to the ow sensor components);
clean the ow sensor with dry air (like that used for
stove location: respect and check a minimum distance of 10 cm from the wall;
combustion chamber position and cleanliness (clean regularly according to the type of pellet);
smoke duct (clean);
installation (if it does not comply with regulations or the smoke outlet has more than bends);
If you suspect the sensor is malfunctioning, carry out cold tests. If the conditions are changed (for e ample by
opening the door) and the value does not change, there is a sensor problem (DEALER).
he no depression alarm may also occur during ignition, since the ow sensor starts monitoring 90 seconds after
the ignition cycle begins.
heck smoke e tractor function (devolution sensor connection) and board (DEALER).
heck smoke channel for dirt
erify the electrical system and earthing system.
heck eletronic circuit board (DEALER).
(this trips if the thermocouple detects a smoke temperature lower than the value set, which it
interprets as the absence of ames)
urns off due to drop in smoke temperature
lack of pellets
too many pellets have suffocated the ame, check pellet quality (DEALER)
the ma imum thermostat has intervened (rare, this only intervenes in the event of e cessive smoke
temperature) (DEALER)
heck correct functioning of the pressure switch ( A )
(intervenes if a ame fails to appear within a ma imum of 15 minutes, or if ignition
temperature is not reached).
heck correct functioning of the pressure switch ( A )
Distinguish either of the following cases:
heck: - combustion chamber position and cleanliness;
heck that there are pellets in the tank and the re bo
arrival of combustion air in the combustion chamber;
if the heating element is working (DEALER);
room temperature (if lower than
ry to light with a relighter (see page 4).
heck: (only by the Dealer)
if the thermocouple is working (DEALER);
start-up temperature setting in the parameters (DEALER).
Repeat start up after having emptying the brazier.
(not a defect of the stove).
heck electricity connection and drops in voltage.
(intervenes if the thermo coupling has failed or is disconnected).
heck connection of thermo coupling to board: check function in cold test (DEALER).
keyboards);
(this trips if the smoke e traction speed sensor detects a fault)
use a relighter) and damp.