POSSIBLE TROUBLESHOOTING
4) Block_FI/NO Start (intervenes if the flame fails to appear within a maximum of 15 minutes, or if the ignition tem-
peratuse is not reached). Shuts down due to incorrect smoke temperature during ignition. Distinguish either of the
following cases:
The flame has NOT appeared
Verify:
• positioning and cleanliness of combustion chamber
• functionality of the ignition resistance
• room temperature (if lower than 3 °C a firelighter is
needed) and moisture content. Try to ignite with a
firelighter.
5) Failure/Power
Shuts down due to an electricity failure
Check electricity connection and drops in voltage.
6) Fault/RC (intervenes if thermocouple fails or is disconnected)
Shuts down due to a failure or disconnection in the thermocouple
Check connection of thermocouple to the control board: verify functionality in a cold test.
7) Smoke °C/high (shuts down due to excessive smoke temperature)
Shuts down due to maximum smoke temperature being exceeded.
An excessive smoke temperature may occur because of the following: pellet type, anomaly in smoke extraction,
blocked channel, incorrect installation, gear motor 'drift' or no air intake in the room.
During ignition, the differential switch trips
- check moisture content of ignition resistance
- 'Battery check': indicates that the buffer battery needs changing
Warnings
Warnings are shown until you intervene and press the 0/1 key on the control panel.
Do not ignite the stove until the problem has been checked and resolved.
Should it block, re-ignite the stove after allowing it to shutdown (10 minutes with an audible signal), then press the 0/1
key.
Never unplug the device during the shutdown process.
It is important for the DEALER to know what warning signal appears on the panel.
If problems occur which you are not able to resolve directly, and in the case of any form of complaint, contact the
DEALER which carried out commissioning and/or the retailer, indicating the warranty slip number and the purchase
receipt reference.
The flame has appeared but after Ignition appears on
the display, Block_FI/NO Start appears.
Verify:
• thermocouple functionality
• set parameters for ignition temperature
52