Models; Submersible Applications; Submersible Psc And Surface Applications - Franklin Electric SUBDRIVE UTILITY Manual De Instrucciones

Ocultar thumbs Ver también para SUBDRIVE UTILITY:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PRODUCT INFORMATION

Models

Models

Submersible Applications

Model
SubDrive Utility UT2W
- w/Pressure Sensor
SubDrive Utility UT2W
- w/Pressure Transducer
Motor and pump HP are programmed through DIP switch settings. Refer to
Wire Submersible Motor Series (DIP SW1 – Positions 1–7)" on page

Submersible PSC and Surface Applications

Model
SubDrive Utility UT2W
- w/Pressure Sensor
SubDrive Utility UT2W
- w/Pressure Transducer
SubDrive Utility will operate many submersible PSC and Franklin Electric surface mounted pumps,
including C1, MH, BT4, DDS, and VersaJet series.
NOTE: Recommended for use on inverter duty rated motors. Follow motor manufacturer recom-
mendations for cable lengths when using variable frequency drives.
When operating a PSC or surface system, drives are configured based on motor current capacity
rather than horsepower. Motor current capacity is programmed through DIP switch settings. Refer
to
"Maximum Amps (DIP SW1 – Positions 1–5)" on page
8
115 V 2-Wire
Part Number
1/3 HP
5870202003
5870202003XD
115 or 230 V 2-Wire Motor Overload Protection Ratings (Amps)
Part Number
4.6
4.7
5870202003
5870202003XD
1/2 HP
1/2 HP
"Franklin Electric 2-
24.
5.0
6.0
6.2
6.4
8.1
8.4
25.
230 V 2-Wire
3/4 HP
1 HP
9.1
9.5
9.8 10.0 10.4 11.0 12.0 13.1
1.5 HP

Publicidad

Tabla de contenido
loading