PRODUCT INFORMATION

Models

Models

Submersible Applications

Model UT3P
w/Pressure Sensor
w/Pressure Transducer
Motor and pump HP are programmed through DIP switch settings. Refer to
power Setting (DIP SW1 – Positions 1–5)" on page
Surface Applications
Model UT3P
w/Pressure Sensor
w/Pressure Transducer
The drive will operate many Franklin Electric surface mounted pumps, including C1, MH, BT4, DDS, and
VersaJet Pro series.
When operating a surface system, drives are configured based on motor current capacity rather than horse-
power. Motor current capacity is programmed through DIP switch settings. Refer to
SW1 – Positions 1–5)" on page

Pump Sizing and Performance

Maximum pump output using the drive is similar to the performance achieved using a pressure switch.
Therefore, the pump selection criteria are the same as if a pressure switch were used.
NOTE: The drive may result in 85-90% of pump performance when compared to other drive models, espe-
cially in applications with reduced input voltage.
Refer to the Franklin Electric AIM Manual for specific sizing information.
If a pump and motor as described above are already installed in the system, and the well system compo-
nents are in good working order, no further system upgrades are required. However, if an existing pump and
motor have not been properly evaluated, or if the components of the well system are not in good working
order, the drive cannot be used to correct the problem or extend the life of aging components.

Generator Sizing

Basic generator sizing for the drive is 1.5 times the maximum input watts consumed by the drive, rounded
up to the next normal-sized generator.
Recommended minimum generator sizes for the drive:
3500 watts nominal for up to 1 HP
5000 watts nominal for up to 2 HP
IMPORTANT: Do not use with a Ground Fault Circuit Interrupter (GFCI). If using an externally regulated gen-
erator, verify that the voltage and frequency are appropriate to supply the drive. This drive has not been
tested with inverter-controlled generators and AC-DC inverters.
8
Part Number
½ HP
5870202303
5870202303XD
22.
230 V 3-Phase Motor Overload Protection Ratings (Amps)
Part Number
2.6 3.0 3.6 3.8 4.0 4.1 4.6 4.7 5.3 5.9 6.2 6.6 6.8 8.1 8.5 8.6
5870202303
5870202303XD 
23.
230 V 3-Wire and 3-Phase
¾
HP
1 HP
1 ½ HP
"Submersible Motor Horse-
"Maximum Amps (DIP
2 HP