Before installing, vacuum the inside space of the extraction unit and clean the sealing surface!
EN
Installing the new fine filter:
⇒ Place the rear edge of the fine filter into the guide
rails (27), push in completely and flip up and close.
⇒ Insert fixing screws (25, Fig. 25) and screw closed.
⇒ Replace the cover plate and close with the screws.
⇒ First place the base of the front panel onto the unit,
then push the upper part of the panel against the
snap fasteners to close.
If it is not possible to close the cover plate, then
the fine filter has not been completely returned
into the housing, or the fine filter is situated
too low due to the fact that the fixing screws
(25, Fig. 25) have not been tightened sufficiently.
6.3

Safety Fuses

Repeated triggering of a device protection switch is caused by a defect in the suction device.
Send the device in for repair!

6.3.1 Extraction

The protection of the suction device is achieved by two device
protection switches (14).
If an overload switch is released, it can be reset by pressing the
button back in.

6.3.2 Quattro Control-Box

The Quattro Control-Box is protected with 2 fine wire fuses.
Replace fuses only with suitable fuses stating the specified
data, see section 8.2. Technical Data.
Never install fuses with greater values.
Changing the fuses:
⇒ Unplug the power cable from the QCB.
⇒ Using a screwdriver, dismantle the fuse holder (27) and pull
out as far as it will go.
⇒ Remove the defect fuse and replace with a new fuse in the
same position (close to the housing).
⇒ Insert the fuse holder as far as it will go, until it locks in
place.
27
27