FLASHING
LIGHT
14 - 15 **
(LED CABI-
NET)
ELECTRO-
MAGNET
16 - 17* **
(VANDAL-
PROOF)
16 - 18* ** BAR LED
(WHITE)
19 - 20*
2
CH RADIO
nd
21 - 22
AERIAL
23 - 24 -
MOTOR
28 - 29
25 - 26 - 27 OPTIONAL
ENCODER
30 - 31 - 32 MAIN
ENCODER
* The outlets can be configured using the TAUPROG (see relative instructions). The standard configu-
ration is shown in the table.
**
If Jumper 6 is not plugged in, energy saving mode will be activated and, at the end of each
manouvre, outputs 11-12, 12-13, 14-15, 16-17 and 16-18 will be switched off.
Terminals 23-24 must be used in parallel to 28-29 in the case of LUXE automatic barriers
(you have to observe the same polarity between the 2 outputs).
Terminals 25-26-27 are available if the circuit present on the K206MA relative to the en-
coder, terminals 30-31-32, is faulty
IMPORTANT:
•
Do not connect auxiliary relays or other devices tot he 18 V DC output (terminals 11 – 12) to
avoid malfunctions of the control unit. Use separated power supply / transformers instead;
•
do not connect switching feeders or similar apparatus close to the barrier that may be a
source of disturbance;
5. LOGIC ADJUSTMENTS
Make the logic adjustments.
Note: when any adjusting devices (trimmers or dip-switches) on the control panel are operated,
a complete manoeuvre must be carried out in order for the new settings to take effect.
TRIMMER
T.R.A.
not used;
T.C.A.
Automatic Closing time adjustment: from about 0,1 to 12 seconds (see dip-switch no. 1);
FR.
obstacle detection sensitivity adjustment.
Note: by rotating the TRIMMER FR. clockwise the sensitivity of the gearmotor
to obstacles diminishes and therefore the thrust force increases; vice-versa, by
rotating it counter-clockwise, the sensitivity of the gearmotor to obstacles
increases and therefore the thrust force diminishes.
18V DC max. 20W output for flashing light supply, flashing signal supplied
by the control unit, rapid for closing, slow for opening. (14 = POSITIVE - 15 =
NEGATIVE)
Output for vandal-proof
Output for electromagnet to be connected to the end of the rod to hold the
barrier closed (vandal-resistant device). With the barrier closed, the electro-
magnet is constantly powered. Every time a command is given, the electro-
magnet is turned off before the motor starts running.
NEGATIVE)
bar LED power output. (16=POSITIVE - 18= NEGATIVE)
2
radio channel output - for control of an additional automation or for switch-
nd
ing on lights, etc... (N.O. clean contact)
Warning: to connect other devices to the 2nd Radio Channel (area light-
ing, pumps, etc.), use an additional auxiliary relay (see note at end of
paragraph).
WARNING: the default outlet is active monostable 2 sec. To switch it to
active bistable or to modify the activation time it is necessary to use the
TAUPROG hand-held programmer (see relative instructions).
plug-in radio-receiver aerial input , for 433.92 MHz receivers only. (21 =
GROUND - 22 = SIGNAL)
motor supply output 18V DC max. 50 W.
(23-28 = POSITIVE - 24-29 = NEGATIVE).
encoder supply and input (25 = WHITE signal - 26 = BLUE negative - 27 =
See note below.
BROWN positive).
encoder supply and input (30 = WHITE signal - 31 = BLUE negative - 32 =
BROWN positive).
18V DC, 3 W max;
See note below.
17
(16= POSITIVE - 17=