instructions may result in electrical shock, fire hazard,
personal injury or death, damaged equipment,
unsatisfactory performance, and may void manufacturer's
warranty.

Ratings

Refer to serial number label on outside bottom of
enclosure.

Required Materials

• BF15 Pump Controller
• Pump with Motor
Only the following pumps/motors can be used with
the BF15 Controller.
- Balanced Flow Pump Model BFSS2200P or
BFSS2201P
- Pump driven by a Franklin Electric 230V , 3 Phase,
4" Submersible Motor
1
(Model Prefix No's 234511, 234512, 234513, or
234514)
• Tank V6P or larger
• Pressure Relief Valve
• Pressure Sensor
• Pressure Gauge
• Heat Shrink Kit
• (2)
1
" NPT Female fittings for the pressure sensor and
4
gauge
• Copper Wire (see Wire Size table below)
• Circuit Breaker 2 Pole, 20A, 230V
• Disconnect Switch 230VAC 20A
• Pipe and Fittings as necessary
Wire Size AWG
Copper 60°C
14
Insulation
Svc Ent. to Controller
***
Controller to Motor
465
Svc Ent. to Controller
***
Controller to Motor
335
Svc Ent. to Controller
***
Controller to Motor
280
Svc Ent. to Controller
***
Controller to Motor
210
Svc Ent. to Controller
***
Controller to Motor
160
*
Length of cable between controller and motor not to exceed 1000 Ft.
** Wire sized to allow for a 2.5% voltage drop from Service Entrance to controller and 2.5% from controller to motor for a total drop of 5%.
For a total drop of 3%, multiply values by 0.6
*** Minimum size of wire from service entrance to controller is 12AWG
,
3
, 1 or 1
1
HP
2
4
2
Maximum Length of Cable (Feet)
12
10
8
1
HP 230V 3 Phase Motor (2.9A)
2
325
510
805
745
1175
*1000
3
HP 230V 3 Phase Motor (3.8 A)
4
240
380
600
540
850
*1000
1 HP 230V 3 Phase Motor (4.7 A)
200
315
495
455
715
*1000
1
1
HP 230V 3 Phase Motor (5.9 A)
2
155
240
385
335
530
835
BFSS2200P & BFSS2201P Pump/Motor
80
150
235
255
405
640
Table 1: Wire Size Table

2: INSTALLATION

2: INSTALLATION

Pump and Piping

EXPLODING TANK CAN INJURE OR
WARNING
KILL.
• DO NOT install any shut-off valves,
• DO NOT allow tank or pressure relief
• Ensure pressure relief valve is large
For optimum performance, we recommend using the same
size pipe as the pump discharge between the pump and the
tank. Smaller diameter pipe may severely limit the
maximum capacity of the system.
If using a torque arrestor, install it on the discharge pipe
before connecting pipe to the discharge head
Most pumps are assembled with left-hand
CAUTION
threads. Always hold discharge head with
pipe wrench when installing discharge pipe into pump.
Holding casing, motor or motor adapter will allow pump
to unscrew and result in premature pump failure.
To prevent galvanic corrosion, use stainless steel fittings
when discharge head is stainless steel.
If a barb type fitting is used, double clamp where it
connects to drop pipe.
Ensure pressure rating of pipe is higher than maximum
pump discharge pressure. Refer to pump catalog
information or consult supplier for maximum discharge
pressure.
Set pump at least 10' off bottom of well
It is allowable to run branches off of the pipe between the
pump and pressure sensor as long as no devices that could
restrict flow are between the pump and pressure sensor.
Wire Size Table**
6
4
3
1255
1940
2405
935
1445
1790
770
1190
1480
600
935
1160
*1000
375
580
745
*1000
flow control devices, or filters between
pump and pressure sensor.
valve to freeze.
enough to limit tank pressure to a safe
value.
2
1
2940
3585
4360
2185
2665
3235
1805
2205
2680
1425
1750
2140
925
1160
1445
0
00
3935
3260
2620
1805
3