Specifications
K-45 Line Capacity
Cable Size
1
/
" (6mm)
4
5
/
" (8mm)
16
5
/
" (8mm)
IC (Inner Core)
16
3
/
" (10mm)
8
See Accessories section for a listing of available cables and lengths.
Slide Action Chuck
Hand Grip
Cable
Variable Speed
ON/OFF Switch
GFCI
(If Equipped, 120V Units)
Figure 1 – K-45 Drain Cleaning Machine With Slide
Action Chuck
Motor Type ....................Universal
Motor Rating
120V Motor.................
120VAC single phase
3.2 amp, 50/60Hz
230V Motor.................
230V ˜, 50/60Hz , 2,2 A, 280W
ON/OFF Switch .............Variable Speed Reversing
No Load Speed .............0-650 r/min (RPM)
Drain Line Capacity .......
3
Weight w/C1-IC Cable
Manual Feed...............12.6 lbs. (5.7kg)
AUTOFEED Feed .......13.8 lbs. (6.3kg)
Sound Pressure (L
)* .......73 dB(A), K=3
PA
Sound Power (L
)*...........84 dB(A), K=3
WA
Vibration* ............................<2.5 m/s
* Sound and vibration measurements are measured in accordance with a stan-
dardized test per Standard EN 62481-1.
- Vibration levels may be used for comparison with other tools and for pre-
liminary assessment of exposure.
- Sound and vibration emissions may vary due to your location and specific use
of these tools.
- Daily exposure levels for sound and vibration need to be evaluated for
each application and appropriate safety measures taken when needed.
Evaluation of exposure levels should consider the time a tool is switched off
and not in use. This may significantly reduce the exposure level over the total
working period.
999-998-285.08_REV. E
Recommended Line Size
3
/
" to 1
1
/
" (19mm to 38mm)
4
2
3
/
" to 1
1
/
" (19mm to 38mm)
4
2
1
1
/
" to 2" (32mm to 50mm)
4
1
1
/
" to 2
1
/
" (32mm to 64mm)
4
2
Drum
FORWARD/
REVERSE
Switch
Double Insulated
Double Insulated
/
" (19mm) thru 2
1
/
" (64mm)
4
2
2
, K=1.5
K-45 Drain Cleaning Machine
Slide Action Chuck
Hand Grip
Cable
Advance
Retrieve
Feed
Feed
AUTOFEED
Lever
Lever
GFCI
(If Equipped, 120V Units)
Figure 2 – K-45 AF Drain Cleaning Machine With AUTO -
FEED
Figure 3 – Machine Serial Number
The machine serial number is located on the underside
of the power unit. The last 4 digits indicates the month and
year of the manufacture. (04 = month, 10 = year).
Standard Equipment
All K-45 Drain Cleaning Machines come with one pair of
RIDGID Drain Cleaning gloves.
NOTI E
This machine is made to clean drains. If prop-
erly used it will not damage a drain that is in good condi-
tion and properly designed, constructed and maintained.
If the drain is in poor condition, or has not been properly
designed, constructed and maintained, the drain cleaning
process may not be effective or could cause damage to
the drain. The best way to determine the condition of a
drain before cleaning is through visual inspection with a
camera. Improper use of this drain cleaner can damage
the drain cleaner and the drain. This machine may not
clear all blockages.
Drum
Warning
Label
FORWARD/
REVERSE
Switch
Variable Speed
ON/OFF Switch
Date Code
5