GE JGP18 Guía De Uso, Cuidado E Instalación página 20

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION INSTRUCTIONS
MINIMUM SPACING REQUIREMENT
When installing a double bay downdraft cooktop
in combination with another downdraft cooktop
maintain the minimum spacing between units as
shown below. Installing them too close will affect
cooking performance.
18"
45.7 cm
Double Bay
18"
45.7 cm
Double Bay
18"
45.7 cm
16
1
41 cm
Single Bay
20
"
4
3
8
11.1 cm
Double Bay
"
4
3
8
11.1 cm
Single Bay
"
8
Double Bay
(continued)
STEP 1
INSTALLING CABINETS OVER YOUR COOKTOP
25"
(63.5 cm)
36"
(91.4 cm)
Avoid placing cabinets above the cooktop unit,
if possible, in order to reduce the hazards caused
by reaching over heated surface units.
If the cabinets are installed above the cooktop,
allow a minimum 30" (76.2 cm) clearance
between the cooking surface and the bottom of
the cabinet.
A non-combustible material must be installed on
the under side of the cabinet. Use a flame
retardant millboard at least 1/4" (6.3 mm) thick,
or gypsum board at least 3/16" (4.7 mm) thick,
covered with 28 gauge sheet steel or 0.020"
(.5 mm) thick copper. The maximum depth of
cabinets above the cooktop is 13 inches (33 cm).
EXCEPTION: Installation of a listed microwave
oven or cooking appliance over the cooktop shall
conform to the installation instructions packed
with that appliance.
Working areas adjacent to the cooktop should
have an 18" (45.7 cm) minimum clearance
between the countertop and the bottom of the
cabinet. If the clearance is less than 18"
(45.7 cm), the adjacent cabinets should be at
least 2" (5.08 cm) from the side of the cooktop.
30" min
(76.2 cm)
13"
(33.02 cm)
30"
18"
(76.2 cm)
(45.7 cm)
2" min to wall
(5.08 cm)
2" min to wall
We recommend
(5.08 cm)
at least 6"
We recommend
(15.24 cm) for
at least 6"
best venting
(15.24 cm) for
performance.
best venting
performance.