Gas Connection - GE JGP18 Guía De Uso, Cuidado E Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

STEP 6
PREPARE FOR DUCTWORK
NOTE: Ductwork MUST be vented outside. DO
NOT vent into a wall, ceiling, crawlspace, attic or
any concealed space.
Determine the best route for ductwork; it can be
routed in a variety of ways depending on the
kitchen layout.
Typical duct arrangement countertop series.
Inside wall
"X10"
3
1
cabinet
4
(8.2 cm X 25.4 cm)
Transition elbow
Up inside wall to roof or
overhang.
Peninsula or island
Between floor joists.
Optional duct arrangement under concrete slab.
NOTE: PVC sewer pipe type PSM 12454-B
Schedule 40 ASTM D1785.
Wall cap
6" (15 cm) Dia.
Metal Duct
12"
(30 cm)
Min.
6"
(15 cm)
Dia. PVC
coupling
30" (76.2 cm)-0" Max
6" (15 cm) Dia.
Pack tightly with gravel
PVC Sewer pipe
or sand completely
elbow
around pipe.
22
INSTALLATION INSTRUCTIONS
Outside wall
cabinet
Directly to outside.
Peninsula
"X10"
3
1
4
(8.2 cm X 25.4 cm)
Thru cabinet toe space.
5" to 6"
(12.7 cm to 15 cm)
6" (15 cm)
Metal transition
Dia. 90°
Metal Elbow
Concrete
slab
16"
6" (15 cm)
(40.6 cm)
Dia. PVC
Max.
Sewer Pipe
6" (15 cm) Dia.
PVC Sewer pipe
elbow
(continued)
STEP 7

GAS CONNECTION

Make the gas connection
to the inlet of the
pressure regulator
on this appliance
with a 1/2" pipe
nipple with male
pipe thread. Use
an approved pipe
joint compound
resistant to the
action of LP gas at
pipe connections.
Install a manual shut-off
valve in the gas line in
an easily accessible
location, as close to the
pipe stub as possible,
making allowances for
the ventilation ducting.
Be sure you know how and where to shut off the
gas supply to the cooktop.
NOTE:
Instead of using solid piping to connect to
pressure regulator, an approved flexible metal
appliance connector may be used between the
pipe stub and shut off valve and the pressure
Transition
regulator, if local codes permit.
elbow
Appropriate flare union adapters are required at
each end of the flexible connector.
Turn on the gas; check for leaks using a liquid
leak detector at all joints in the system.
CAUTION: DO NOT USE A FLAME
TO CHECK FOR GAS LEAKS.
6" (15 cm)
IMPORTANT—Disconnect the cooktop and the
Dia. Metal
individual shut off valve from the gas supply
duct
piping system during any pressure testing of that
system at test pressures greater than
Isolate the cooktop from the gas supply piping
system by closing the individual manual shut off
valve to the cooktop during any pressure testing
of the gas supply piping system at test pressures
6"
(15 cm)
equal to or less than
Dia.
PVC
coupling
6" (15 cm)
Dia. PVC
Sewer
pipe
Gas appliance
pressure
regulator
1/2" Threaded
pipe nipple
Shut-off valve
Pipe stub
1
PSIG.
2
PSIG.
1
2

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Jgp389

Tabla de contenido