CONVERT GRILL BURNER AIR SHUTTER
(on some models)
Air Opening
Air Shutter
Insert screwdriver blade in slot and
twist with slight pressure to allow air
shutter to slide easily.
The left hand air shutter controls the rear half of
the grill burner; the right hand shutter controls
the front half.
Slide air shutter backward or forward to increase
or decrease the size of the air opening. Air shutters
fit snugly on the grill burner, so a screwdriver
blade may be required to make this adjustment
(see illustration). The snug fit of the air shutter
assures it will remain positioned correctly.
6

CHECK FOR LEAKS

When all connections have been made, make sure
all cooktop controls are in the off position and turn
on the main gas supply valve. Use a liquid leak
detector at all joints and connections to check for
leaks in the system.
CAUTION: DO NOT USE A FLAME TO
CHECK FOR GAS LEAKS.
When using test pressures greater than
pressure test the gas supply system of the residence,
disconnect the cooktop and individual shut-off valve
from the gas supply piping. When using test pressures
of
PSIG or less to test the gas supply system,
1
2
simply isolate the cooktop from the gas supply
system by closing the individual shut-off valve.
7
1. Light the top burners and continue turning all
of the surface knobs to LOW.
2. Remove all 4 knobs.
3. With a small flat blade
screwdriver, turn the
valve set screws
clockwise to decrease
flame size,
counterclockwise to
increase flame size.
Adjust until the flame is
about the same height as
the top of the burner.
4. Replace the knobs.
8
The combustion quality of burner flames needs
to be determined visually.
If burner flames look like (A), call for service.
Normal burner flames should look like (B) or
(C), depending on the type of gas you use.
With LP gas, some yellow tipping on outer cones
is normal.
1
PSIG to
2
ADJUST LOW FLAME SETTING
Clockwise
to reduce
flame size.
CHECK QUALITY OF FLAMES
(A) Yellow flames—Call for service
(B) Yellow tips on outer
cones—Normal for LP gas
(C) Soft blue flames—Normal for
natural gas
Counterclockwise
to increase
flame size.
Valve
Stem