3.7 - DEHUMIDIFICATION MODE (DRY)
a. This mode can be selected by pressing B2 or SW6 until the dehumidification only symbol ( ) is activated
on the remote control and on the control panel display.
b. this mode is similar to cooling mode, except that:
- the internal fan speed cannot be set and is forced to minimum (B6/B7 and SW2 are disabled);
- the desired ambient temperature ("set temperature") cannot be selected (B4/B5 and SW4/SW5 are
disabled). the air conditioner will operate to keep the initial ambient temperature all but unchanged.
3.8 - ECO FUNCTIONING
a. this mode can be selected by pressing B2 on the remote control until symbol a appears on the remote
control display or by pressing SW6 until symbol eCo appears on the control panel display.
b. in this mode, the CoolinG and fan functions are selected automatically depending on the continuously
monitored room temperature value to ensure that there is a perfect comfort-level in the conditioned room.
FOR SILENT MODEL ONLY:
on selecting minimum ventilation speed, the external fan speed is also reduced resulting in a considerably
quieter running appliance.
With particularly low ambient temperatures, the external fan speed is always forced
to maximum.
3.9 - NIGHT FUNCTION
a. this mode can only be selected from the remote control (by pressing B11) and can only be used in con-
junction with cooling or heating modes (HP only).
b. When this function is enabled in cooling mode, the internal fan is forced to minimum speed and the set
ambient temperature increases automatically by one degree after the first hour and by a further degree
after the second hour of operation (from activation of the function or from the subsequent change in set
temperature).
c. if, on the other hand, this function is activated in heating mode ( HP only), the internal fan is forced to
minimum speed and the set ambient temperature decreases automatically by one degree after the first
hour and by a further degree after the second hour of operation (from activation of the function or from
the subsequent change in set temperature).
d. to deactivate the function, press key B11 again.
With particularly low ambient temperatures, the external fan speed is always forced
to maximum.
EN - 19