Commissioning
2
Mounting
Mounting through bore holes in the housing for M4 screws or using the
BTU 0300M-W, BT 300 W, BT 56, BT 300-1 mounting system (accessories).
NOTE
Degree of protection IP 65 is achieved only if the connectors and caps are
screwed into place!
3
Electrical connection – Commissioning with factory settings
 Connect the BPS 3xxi via MS 3xx, MK 3xx, ME 3xx or KB 30x.
 Connect voltage supply and, if necessary, switching input, USB service inter-
face and host/bus interface.
 Switch on operating voltage, PWR LED must illuminate green.
 Position the bar code tape in front of the BPS, at a distance of approx. 100mm.
 After successful determination of the position, the PWR LED is permanently lit
green.
LED indicators
OFF
Green, flashing
Green, continuous light Device ready
Red, flashing
PWR LED
Red, continuous light
Orange,
continuous light
Orange, flashing
Off
Green, flashing
Green, continuous light Bus operation ok
BUS LED
Red, flashing
Red, continuous light
Orange, flashing
Device switched off
Device initialized
Warning
Device error
Service active
PROFINET wave function
No operating voltage
Bus/interface initialization
Communication error
Network error
PROFINET wave function
EN
17