Metrohm 758 KFD Titrino Instrucciones Para El Uso página 86

Ocultar thumbs Ver también para 758 KFD Titrino:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

3.2 Remote control commands
*Parameter
SET1
.
│ ├
.EP
Endpoint 1
│ ├
.UnitEp
│ ├
.Dyn
│ ├
.UnitDyn
│ ├
.MaxRate
│ ├
.MinRate
│ ├
.Stop
│ │ ├
.Type
│ │ ├
.Drift
│ │ ├
.Time
│ │ ├
.StopT
SET2
.
TitrPara
.
│ ├
.Direction
│ ├
.XPause
│ ├
.Start V
│ │ ├
.Type
│ │ ├
.V
│ │ ├
.Factor
│ │ ├
.Rate
│ ├
.Pause
│ ├
.ExtrT
│ ├
.DosUnit
│ │
│ ├
.MeasInput
│ ├
.Ipol
│ ├
.Upol
│ ├
.PolElectrTest
│ ├
.Temp
│ ├
.TDelta
│ │
StopCond
.
│ ├
.VStop
│ │ ├
.Type
│ │ ├
.V
│ │ ├
.Factor
│ ├
.FillRate
│ │
Statistics
.
│ ├
.Status
│ ├
.MeanN
│ ├
.ResTab
│ │ ├
.Select
│ │ ├
.DelN
│ │
Presel
.
│ ├
.Cond
│ ├
.DriftDisp
│ ├
.DCor
│ │ ├
.Type
│ │ ├
.Value
│ ├
.IReq
│ ├
.SReq
│ ├
.LimSmplSize
│ │ ├
.Status
│ │ ├
.LoLim
│ │ ├
.UpLim
│ ├
.ActPulse
82
Tree part "Parameters for SET"
Control parameters for EP1
depends on meas.quant.
Unit of endpoint
Dynamics
Unit of dynamics
Maximum dosing rate
Minimum dosing rate
Titration stop
Type of stop criterion
Stop drift
Switch-off delay time
Stop time
Control parameters for EP2, as for EP1
Titration parameters
Titration direction
Waiting time before start volume
Start volume
Type of start volume
Volume for absolute start volume
Factor for relative start volume
Dispensing rate for start volume
Waiting time after start volume
Extraction time
Selection of the dosing unit
Measuring input
Polarization current
Polarization voltage
Test for polarized electrodes
Titration temperature
Time interv. for meas.acquisition
Stop conditions
Stop volume
Type of stop volume
Volume for absolute stop volume
Factor for relative stop volume
Filling rate
Statistics
Status of statistics calculation
No. of individual determinations
Result table
Deletion of individual results
Preselections
Conditioning
Display of drift during cond.
Drift correction
Type of drift acquisition
Drift value for manual drift corr.
Request of Id's after start
Request of smpl size after start
Limits for sample size
Status of limit control
Lower limit
Upper limit
Output of a pulse
3.2.2.12.
read only
depends on meas.quant. 3.2.2.13.
read only
0.01...10...150, max.
0.01...25.0...9999
drift, time
1...20...999
0...10...999, inf
0...999999, OFF
+, –, auto
0...999999
abs., rel., OFF
0...999.99
0...±999999
0.01...150.0, max.
0...999999
0...999999
internal D0, external D1,
external D2
1, 2, diff.
0...1...±127
0...400...±1270
ON, OFF
–170.0...25.0...500.0
1...2...999999
abs., rel., OFF
0...99.99...9999.99
0...±999999
0.01...150.0, max.
ON, OFF
2...20
original,delete n,delete all
1...20
ON, OFF
ON, OFF
auto, man., OFF
0.0...99.9
id1, id1&2, all, OFF
value, unit, all, OFF
ON, OFF
0.0...999 999
0.0...999 999
first, all, cond., OFF
ditto
ditto
ditto
ditto
3.2.2.14.
ditto
ditto
ditto
3.2.2.15.
3.2.2.16.
3.2.2.17.
ditto
ditto
ditto
3.2.2.18.
3.2.2.19.
3.2.2.20.
3.2.2.21.
ditto
ditto
ditto
3.2.2.22.
3.2.2.23.
3.2.2.24.
ditto
ditto
3.2.2.25.
3.2.2.26.
ditto
ditto
ditto
3.2.2.27.
ditto
ditto
ditto
3.2.2. 28.
ditto
3.2.2. 29.
ditto
ditto
ditto
3.2.2.30.
758 KFD Titrino

Publicidad

Tabla de contenido
loading

Tabla de contenido