Ac Voltage (Frequency, Duty Cycle) Measurements - RS Pro RS-9985 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Insulation Tester with Multimeter / English

AC VOLTAGE (FREQUENCY, DUTY CYCLE) MEASUREMENTS

WARNING: Risk of Electrocution. The probe tips may not be long enough to contact
the live parts inside some 240 V outlets for appliances because the contacts are
recessed deep in the outlets.
As a result, the reading may show 0 V when the outlet actually has voltage on it.
Make sure the probe tips are touching the metal contacts inside the outlet before
assuming that no voltage is present.
CAUTION: Do not measure AC voltages if a motor on the circuit is being switched
ON or OFF. Large voltage surges may occur that can damage the meter.
1. Set the function switch to the green VAC/Hz/%
position.
2. Insert the black test lead banana plug into the
negative COM jack.
Insert red test lead banana plug into the positive
V jack.
3. Touch the black test probe tip to the neutral side
of the circuit.
Touch the red test probe tip to the "hot" side of
the circuit.
4. Read the voltage on the main display and the
frequency in the right auxiliary display
5. Press and hold the MODE button for 2 second to
indicate "Hz".
6. Read the frequency on the main display.
7. Press the MODE button to indicate "%".
8. Read the % of duty cycle on the main display.
9. Press EXIT for 2 seconds to show the function
of AC+DC. Test DC and AC TURE rms.
6
MV VOLTAGE MEASUREMENTS
CAUTION: Do not measure mV voltages if a motor on the circuit is being switched
ON or OFF. Large voltage surges may occur that can damage the meter.
1. Set the function switch to the green mV position.
2. Press the MODE button to indicate "DC".or "AC ".
In AC range press EXIT for two seconds and
chose "AC+DC"
3. Insert the black test lead banana plug into the
negative COM jack.
Insert the red test lead banana plug into the
positive V jack.
4. Touch the black test probe tip to the negative side
of the circuit.
Touch the red test probe tip to the positive side of
the circuit.
5. Read the mV voltage on the display.
25/01/2018 Version No. 001
25/01/2018 Version No. 001
Insulation Tester with Multimeter / English
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

161-1630

Tabla de contenido