A1
Antenna shield
A2
Antenna
Opening control for the connection of control
P1
devices with N.O. contact
Opening controls for pedestrian access for the
P2
connection of control devices with N.O. contact
P3
Stop command. N.C. contact
P4
Common (-)
Safety ribbons.
P5
N.C. contact or conductive rubber ribbons
P6
Photocell. N.C. contact
P7
Opening end of stroke. N.C. contact
P8
Closing end of stroke. N.C. contact
P9
Common (-)
P10 - P11
Power output 24 VAC for photocells and other
accessories
P11 - P12
Photocell TX power supply for functional test
P13 - P14
Electric lock 12VAC
ELECTRIC CONNECTIONS TABLE
G1 - G2
G3
G4
G5
G6 - G7
L
N
F1
MAINS
OVERLOAD
OP
PA
CL
40
Courtesy light
Motor opening
Motor common
Motor closing
Flashing light
230VAC 40W (City4) / 120VAC 40W (City4-120V)
Power phase 230VAC / 120VAC
Neutral 230VAC / 120VAC
5A (City4) / 8A (City4-120V)
interface
It shows that the control unit is power supplied
It shows that there is an overload on accessories
power supply
Opening in progress
Pause (gate opened)
Closing in progress