DISPLAY DATA
DESCRIPTION
dEF.
no
It does not load the V2 ELETTRONICA standard data
SCor
Predefined programming for a typical sliding gate
AntE
Predefined programming for a typical two-door gate
t.AP
0.0" ÷ 2.0'
Gate opening time
t.APP
0.0" ÷ t.AP
Opening time of pedestrian gate
t.Ch
0.0" ÷ 2.0'
Gate closing time
t.ChP
0.0" ÷ t.Ch
Closing time of pedestrian gate
t.SEr
0.5" ÷ 2.0'
Electrical lock operation time
no
- Lock is not energized (it corresponds to 0)
t.ASE
0.0" ÷ 2.0'
Lock advance time
t.inv
0.5" ÷ 2.0'
Backlash time
no
- Backlash disabled (it corresponds to 0)
t.PrE
0.5" ÷ 2.0'
Pre-flashing time
no
- Pre-flashing disabled (it corresponds to 0)
Pot
30 ÷ 100%
Motor power
SPUn
no / Si
Start off
t.P.So
0.5" ÷ 3.0"
Slowed down starting time
no
- Slowed down starting disabled
t.raL
0.5"÷22.5"
Slow down time
no
- Slow down disabled
t.CVE
0.0" ÷ 3.0"
Fast closing time after slowing down during closing
St.AP
Start in opening
no
- Start command is not available
ChiU
- Command close gate
PAUS
- Stop the gate and goes in pause
St.Ch
Start in closing
Stop
- Start command stop the gate
APEr
- Start command open the gate
St.PA
Start in pause
no
- Start command is not available
ChiU
- Start command closes the gate
SPAP
Pedestrian in opening
no
- Pedestrian start command is not available
ChiU
- Pedestrian start command closes the gate
PAUS
- Gate goes in pause
Ch.AU
Automatic closing
no
- The gate closes after the setup time)
0.5"÷ 20.0'
- The automatic closing is not active (it corresponds to 0)
Ch.tr
Closing after passage
no
- Closing after passage disabled
0.5"÷ 20.0'
- Gate stop for a time to be set between 0.5" to 20'
PA.tr
no / Si
Pause after transit
LUCI
Courtesy Light
t.LUC
- Lights start time adjustable from 0 to 20'
CiCL
- Lights are on trough the whole cycle
AUS
- Auxiliary output
tiM
- Timed aux out (from 0 to 20')
biSt
- Aux out relay with bistable functioning
Mon
- Aux out relay with monostable functioning

City4 FUNCTION TABLE

38
38
DEFAULT
DEFAULT
MEMO
Ante
SCor
DATA
no
no
22.5"
22.5"
6.0"
6.0"
23.5"
23.5"
7.0"
7.0"
2.0"
no
1.0"
0.0"
no
no
1.0"
1.0"
60
60
Si
no
no
1.5"
6.0"
6.0"
1.0"
0.0"
PAUS
PAUS
StoP
StoP
ChiU
ChiU
PAUS
PAUS
no
no
no
no
no
1'00
1'00

Hide quick links:

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

City4

Tabla de contenido